Stainless steel 200a n, Plasma / h, O shield – Tweco XT-300 Torch for OEM UC-300 User Manual

Page 49: This art is for reference only

Advertising
background image

Manual 0-4829 Rev AN

8-51

TORCH DATA for Ultra-Cut

(ga)

(in)

inch

(PSI)

(Ball) (PSI) (Ball) (PSI)

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

3/8

0.375

20

80

90

5

55

155

0.160

95

0.300

0.0

0.110

1/2

0.500

20

80

90

5

55

156

0.160

85

0.300

0.4

0.115

5/8

0.625

20

80

90

5

55

158

0.180

65

0.300

0.5

0.122

3/4

0.750

20

80

90

5

55

163

0.200

50

0.300

0.7

0.133

7/8

0.875

20

80

90

5

55

177

0.250

40

0.400

0.9

0.149

1

1.000

20

80

90

5

55

183

0.300

35

0.450

1.0

0.148

1 1/4

1.250

20

80

90

5

55

185

0.300

20

0.176

1 1/2

1.500

20

80

90

5

55

200

0.350

10

0.211

1 3/4

1.750

20

80

90

5

55

207

0.350

8

0.216

(Bar)

(Ball) (Bar) (Ball) (Bar)

Volts

(mm)

±0.1

(mm/min)

(mm)

(sec)

(mm)

1.4

80

6.3

5

3.8

155

4.1

2400

7.6

0.0

2.8

1.4

80

6.3

5

3.8

156

4.1

2000

7.6

0.4

2.9

1.4

80

6.3

5

3.8

157

4.4

1550

7.6

0.5

3.1

1.4

80

6.3

5

3.8

165

5.1

1100

7.6

0.7

3.4

1.4

80

6.3

5

3.8

183

7.6

900

11.4

0.9

3.7

1.4

80

6.3

5

3.8

185

7.6

500

4.5

1.4

80

6.3

5

3.8

200

8.9

250

5.4

1.4

80

6.3

5

3.8

206

8.9

200

5.5

(PSI) /

(Bar)

(Ball)

(PSI) /

(Bar)

(Ball)

(PSI) /

(Bar)

Volts

in ±0.005 /

mm ±0.1

ipm /

mm/min

in ±0.005 /

mm ±0.1

(sec)

15

60

80

0.120

300

0.120

1.0

4.1

5.5

3.0

7600

3.0

140

0

Plasma (N

2

) Shield

(N

2

)

80

NA

Marking

20A Arc Current

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Transfer

Height

Pierce

Delay

Marking

quality

degrades

as

thickness

decreases

Plasma Gas

Distributor

Electrode

Cartridge

Shield

Retainer

Shield Cap

Shield Gas

Distributor

Tip

22-1043

22-1089

22-1022

22-1015

22-1049

22-1284

22-1067

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Kerf Width

@ Rec.

Speed

Plasma (N

2

)

Shield
(H

2

O)*

Edge Start

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

Plasma (N

2

)

Shield
(H

2

O)*

(mm)

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Edge Start

Edge Start

Edge Start

10
12
15
20

Edge Start

Initial

Piercing

Height

Pierce

Delay

* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.
Note2: Water source used for shield must be demineralized.

Stainless Steel
200A
N

2

Plasma / H

2

O Shield

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later.

44

Edge Start

25

32
38

Cartridge

Electrode

Shield

Shield Gas
Distributor

Tip

Plasma Gas

Distributor

Shield Retainer

Art # A-07917_AC

This Art Is For Reference ONLY

Advertising