3 led test, Led test – Unitec POS4000/V2-Wash Select II User Manual

Page 84

Advertising
background image

P O S 4 0 0 0

Document Number:

POS4007

58

Document Title:

POS4000/V2 WSII Operations Manual

console is assigned unit #1 and the customer interface is assigned unit #2. You should type the
unit number you wish to test followed by the [ENTER] key. The console will briefly display "Wait
Response From" followed by "UNIT n RESPONSE OK" if the test was successful or "UNIT DID
NOT RESPOND" if the test failed.

Example to test link with Unit 2:

[CMD]
[SERVICE]
[6][2][7][4][7]

(password 4)

[MENU UP/DOWN] until "Link Test" is displayed
[ENTER]
[2]
[ENTER]

4.6.3 LED Test

The "LED Test" command is used to test the Light Emitting Diodes (LED) located on the main
console below the POWER LED. To execute this command, press [CMD][SERVICE], provide
password 4, and then select "LED Test" from the secondary menu. At this point, you select from
the following menu:

• Turn All LEDs Off
• Turn Wash-In-Use On
• Turn Out-Of-Serv. On
• Turn LED 3 On
• Turn LED 4 On
• Quit

The following procedure tests each LED:

[CMD]
[SERVICE]
[6][2][7][4][7] Password

4

[ENTER]
[MENU UP/DOWN]

until "LED Test" appears

[ENTER]
[MENU UP]
[ENTER]

Wash-In-Use LED should turn on

[MENU UP]

[ENTER]

Wash-In-Use LED should turn Off, Out-Of-Service LED should turn on

[MENU UP]

[ENTER]

Out-Of-Service LED should turn off, LED 3 should turn on

[MENU UP]

[ENTER]

LED 3 should turn off, LED 4 should turn on

[MENU UP]

[ENTER]

LED 4 should turn off and the commanded is terminated

Advertising