Turn Outer End Cap C.C.W.

No. of Notches or Length on O.D., Inches

HL

3

¹

⁄₂ ”

K - LL

5

²¹

⁄₃₂

SECTION TSM 420

ISSUE

E

PAGE 11 OF 18

14. Still holding the seal cap against the end of the bracket,

place half-moon shaped seal holder plate in position and

tighten the two locknuts uniformly This holds the seal

cap in position and insures proper positioning of seal
NOTE: Do not permit either the inner or outer rotary

member to remain in the shaft in any position other than

their final position for more than 30 seconds since the

rubber bellows of the rotary members have a tendency

to stick to the shaft If the bellows are not in correct

position, the rotary member will be improperly seated

15. Remove tapered sleeve
16. Place the inner bearing spacer collar on the shaft as far

as it will go
NOTE: First replace the snap ring (“HL” size) or half

round rings (“K” - “LL” size) if furnished see figure 15

1. Loosen the square head setscrews over the outer and

inner end caps (two for the HL size, four for the K thru HL

size pumps)

2. Turn the inner end cap clockwise (viewed from shaft

end) until it projects slightly from the bracket exposing

approximately three threads

3. Turn the outer end cap clockwise until the rotor is tight

against the head and the rotor shaft cannot be turned

4. Make a reference mark on the bracket end, opposite a

notch on the other end cap Back off the outer end cap

the required number of notches shown in the table,

see

figure 16.

5. Tighten the inner end cap with a spanner wrench Tap the

spanner wrench lightly but

DO NOT OVER TIgHTEN,

as it will only damage the threads

6. Tighten all the square head setscrews that hold the

inner and outer end caps to prevent their turning in the

bracket

7. The rotor and shaft should turn smoothly for one complete

revolution If the rotor and shaft doesn’t turn smoothly, go

back and repeat the Thrust Bearing Adjustment steps 1

thru 7

17. Press the lip seal (lip toward end of shaft) into the inner

cap and insert the end cap through the shaft end of

bracket With two fingers turn it clock wise (looking at end

of shaft) until it engages the threads The spanner holes

in the wrench cap must be toward the rotor Turn the end

cap with a spanner wrench until it projects slightly into

the opening on the side of the bracket
NOTE: The end cap must not be turned so far that the

lip of the seal drops off the end of the spacer collar on

the shaft or the end cap becomes disengaged with the

threads

, see figure 15.

18. Pack the ball bearing with multi-purpose grease, place

on the shaft and push or gently drive into place in the

bracket

19. Install the lip seal (lip toward end of shaft) and bearing

spacer in the outer end cap and turn the end cap to the

bracket until tight against the bearing,

see figure 15.

*For Viking Old Series 924 Heavy-Duty Refrigeration

Pumps see page 16 for bearing housing disassembly,

assembly and adjusting instructions

20. Put lockwasher and locknut on shaft Insert length of

hardwood or brass through port opening between rotor

teeth to keep shaft from turning Tighten locknut to 50-70

ft - lbs Torque (HL) or 100-130 ft - lbs Torque (K - LL)

THRUST BEARINg ADJUSTMENT

fIgURE 15

fIgURE 16

Bend one tang of lockwasher into slot of locknut If tang

does not line up with slot, tighten locknut until it does

Failure to tighten locknut or engage lockwasher tang

could result in early bearing failure and cause damage

to rest of pump
Remove length of hardwood or brass from port opening

21. Adjust the pump end clearance as indicated in THRUST

BEARINg ADJUSTMENT, below

22. Insert the pipe plug (drain) into the bracket Close the

hand valve and fill the reservoir to within 1½ inches of

the top with the light Refrigeration Oil It is recommended

that the oil be drained and the reservoir be refilled after

the first 200 hours of operation and then after every 1000

hours
NOTE: Re-open the hand valve before the pump is

put into operation The double mechanical seal will not

function properly if it is exposed to ammonia pressure

with this valve closed

SHAfT

LOCKNUT

gREASE fITTINg LOCATION

HALf ROUND

RINgS

INNER

END CAP

NYLON INSERT

SETSCREWS

OUTER END CAP

LOCKWASHER

OUTER SPACER

COLLAR

INNER SPACER

COLLAR

OUTER

LIP SEAL

BALL

BEARINg

INNER LIP SEAL

Advertising