Technical service manual, Warranty – Viking Pump TSM420: HL-LL 4925 User Manual

Page 18

Advertising
background image

SECTION TSM 420
PAgE

18 Of 18

ISSUE

E

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

© 3/2013 Viking Pump Inc.

All rights reserved

TECHNICAL SERVICE MANUAL

WARRANTY

Viking warrants all products manufactured by it to be

free from defects in workmanship or material for a

period of one (1) year from date of startup, provided

that in no event shall this warranty extend more than

eighteen (18) months from the date of shipment from

Viking. The warranty period for Universal Seal series

pumps ONLY (Universal Seal models listed below) is

three (3) years from date of startup, provided that in

no event shall this warranty extend more than forty-two

(42) months from the date of shipment from Viking.
UNDER NO CIRCUMSTANCES SHALL VIKING BE

LIABLE UNDER THIS WARRANTY OR OTHERWISE

FOR SPECIAL, INCIDENTAL, INDIRECT,

CONSEQUENTIAL OR PUNITIVE DAMAGES OF ANY

KIND, INCLUDING, BUT NOT LIMITED TO, LOST

OR UNREALIZED SALES, REVENUES, PROFITS,

INCOME, COST SAVINGS OR BUSINESS, LOST OR

UNREALIZED CONTRACTS, LOSS OF GOODWILL,

DAMAGE TO REPUTATION, LOSS OF PROPERTY,

LOSS OF INFORMATION OR DATA, LOSS OF

PRODUCTION, DOWNTIME, OR INCREASED

COSTS, IN CONNECTION WITH ANY PRODUCT,

EVEN IF VIKING HAS BEEN ADVISED OR PLACED

ON NOTICE OF THE POSSIBILITY OF SUCH

DAMAGES AND NOTWITHSTANDING THE FAILURE

OF ANY ESSENTIAL PURPOSE OF ANY PRODUCT.
THIS WARRANTY IS AND SHALL BE VIKING’S SOLE

AND EXCLUSIVE WARRANTY AND SHALL BE IN

LIEU OF ALL OTHER WARRANTIES, EXPRESS

OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, ALL WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE AND

NON-INFRINGEMENT ALL OF WHICH OTHER

WARRANTIES ARE EXPRESSLY EXCLUDED.
See complete warranty at www.vikingpump.com.

figure 24 shows a typical schematic of a Continuously

Recirculating System with vertical accumulator Space

or other physical requirements may make a horizontal

accumulator more practical As long as the minimum

submergence requirement of 4’ of liquid is maintained, the

arrangement of the accumulator is of little consequence

to good pump operation The schematic is intended only

to show in a general way piping and connections directly

related to the pump No attempt has been made to show all

the necessary controls, valves, regulators, gauges, etc that

are necessary for successful operation of this portion of an

ammonia refrigeration system

fIgURE 24

Schematic of Liquid Ammonia Recirculating System

Pumps on this system run continuously as long as there

is a load on the evaporators The evaporators are flooded

with several times the amount of ammonia needed; this

helps maintain an even temperature in the evaporators The

pressure or head differential across the pump is generally very

low; the only head the pump must develop is that required to

over come any elevation head and any line losses

THROTTLE

VALVE

LIQUID

AMMONIA MAKE

UP LINE fROM

HIgH PRESSURE

RECEIVER

ACCUMULATOR

THROTTLE VALVE

EVAPORATORS

RETURN LINE

fROM PUMP

MOUNTED

RELIEf VALVE

TO

COMPRESSOR

VIKINg REfRIgERATION

AMMONIA PUMP

HEAVY-DUTY REfRIgERATION AMMONIA PUMPS

SERIES 4925