A8005A

Hinge Door Position Switch (DPS)
Installation and Wiring Instructions

FOR INSTALLATION ASSISTANCE, CALL SARGENT AT 1-800-810-WIRE (9473) • www.sargentlock.com

CONTENTS

• DPS Magnet - Low Gauss
• DPS Magnet - High Gauss (colored)
• Reed Switch Assembly with Molex connector
• Stainless steel, brass, and bronze colored Plastic Screw Inserts - (2) each
• O-Rings (2) each
• Installation Instructions
NOTE: Hinge is not included in kit.

PRODUCT DESCRIPTION AND FUNCTION

The DPS retrofits existing door hinges with minimal preparation, by replacing one set of opposing center screws on each hinge leaf with fake
snap-in screw head holding sleeves (looks like a standard screw head).
• The SPST (Single-Pole-Single-Throw) Magnetic Reed Switch actuates when in proximity of a magnet. Circuit breaks when door is opened.
• Both switch and magnet positions are adjustable within their holding sleeves
• The DPS is UL Listed for up to 3 hours as a field installed fire rated accessory
• The DPS is ElectroLynx compatible

The ElectroLynx wiring system is designed to be installation friendly
with quick connectors.

IMPORTANT: ElectroLynx connectors plug and lock together in only
one way, as shown.

Do NOT force connectors together.

Reference ElectroLynx Catalog A7738.

Use appropriate magnet for application:

• Plain Magnet: Low gauss, for wood frame and door

• Colored Magnet: High gauss, for metal frame and door

Refer to following page for step-by-step installation instructions

IMPORTANT

ELECTROLYNX WIRE LOCATIONS AND POSITIONS

1. Caution: Disconnect all input power before servicing.
2. Installer must be a trained, experienced service person.
3. Wiring must comply with applicable local electrical codes,

ordinances and regulations.

POWER

Max Switch Voltage: 100 VDC, 100VAC
Max Switch Current: 0.5 A
Max Load Current: 1.0 A
Power Between Contacts: 10W, VA

DPS

Magnet

4 pin Male

ElectroLynx

®

As part of their promise to provide innovative, fast and effective
higher security solutions to their customers, ASSA ABLOY Group
companies offer ElectroLynx

®

, a universal quick-connect system

that simplifies the electrification of the door opening.

ElectroLynx

®

is a registered trademark of ASSA ABLOY, Inc.