1 A8094A

S1/S2 Replacement Controller Instructions

52-4424, 52-4425, 52-4426

FOR INSTALLATION ASSISTANCE CONTACT SARGENT • 1-800-810-WIRE (9473) • www.sargentlock.com

Through-bolt Screws

1.

On the inside of the door, remove the battery cover’s security screw.

2.

Lift and remove the battery cover.

5.

Disconnect gray ribbon cables, green grounding wire,

motor harness, DPS harness, and hard-wired harness/PoE

(if present). Remove inside assembly from the door.

6.

Remove the four (4) Philips screws holding the original

controller in place. Remove controller.

This controller has been configured as a generic replacement.

The serial number MUST be changed before it can be used!

(For serial configuration see Step #12.)

Security Screw

3.

Remove inside lever (if present).

4.

Remove through-bolt screws on top and bottom of

escutcheon.

7.

Seat the controller into inside escutcheon. Attach with

the four (4) original Philips screws.