Hdf seeding with both compartments – Great Plains 3S-4010HDF Operator Manual User Manual

Page 30

Advertising
background image

26

3S-4010HD and 3S-4010HDF

Great Plains Manufacturing, Inc.

196-522M

03/28/2012

E

HDF Seeding with Both Compartments

A 3S-4010HDF drill can use the fertilizer compartment
for seed (which is still metered by the main seed box
meters).

1.

Clean out both boxes. See “Main Seed Box Clean-
Out
” on page 61
and Fertilizer Box Clean-Out” on
page 61.

Refer to Figure 25
2.

Open the divider door between seed and fertilizer
compartments. To open door, loosen knobs

.

Loosen knobs until bent clips can be turned away
from door

.

3.

When all bent clips have been turned, lift vinyl dew
shield (shown in Figure 26) and flip the flap door
backward over fertilizer-tray openings

.

FigureSpacer:

Refer to Figure 26
4.

With seed/fertilizer flap

covering fertilizer open-

ings, lower vinyl dew shield

to hold flap over fertil-

izer meter cup openings and away from divider.

5.

To avoid unnecessary wear, remove all three fertil-
izer transmission chains. See Seed Rate Manual for
details of Fertilizer drive.

FigureSpacer:

Figure 25

Open Seed/Fertilizer Flap

16383

1

1

1

2

3

1

2

2

3

FigureSpacer:

Figure 26

Flap Secured

16380

4

2

2

4

Advertising
This manual is related to the following products: