Uneven seed depth, Opener disks not turning freely, Meter flutes locked up or shaft twisted – Great Plains 3S-4010HDF Operator Manual User Manual
Page 61: Press wheels not compacting the soil as desired

Great Plains Manufacturing, Inc.
Troubleshooting
57
03/28/2012
196-522M
Uneven seed depth
Excessive field speed
Slow down.
Coulter depth adjustment
Verify coulter-to-opener relationship.
Coulter down-force insufficient -
coulters not achieving depth
Add weight or, if weight is sufficient, increase
coulter spring settings.
Insufficient opener down force for con-
ditions
Adjust row unit cam, page 48.
Conditions too wet
Wait for dryer weather.
Seed-Lok plugging
Damaged or missing seed flap
Replace seed flap.
Damaged opener seed tube
Check for damage at tip of seed tube.
Partially plugged opener seed tube
Lift up drill, expose bottom of seed tube and
clean out.
Incorrect choice of coulter
Change coulter blade.
Skimming (gauge wheels skipping, or
off ground entirely)
Reduce coulter and/or row unit down forces,
or add weights.
Opener disks not turning
freely
Opener plugged with dirt
Clean opener. Adjust scraper.
Planting conditions too wet
Wait until drier weather.
Seed-Lok is plugging opener
Too much blade-to-blade contact
Adjust disk contact. See page 51.
Failed disk bearings
Replace disk bearings.
Bent or twisted opener frame
Replace opener frame.
Meter flutes locked up or
shaft twisted
Obstruction(s) in meter cups
Clean out cups.
Treatment build-up in cups
Disassemble and clean cups/flutes.
Press wheels not com-
pacting the soil as
desired
Too wet or cloddy
Wait until drier weather or rework ground.
Coulter set too shallow
Adjust coulter depth. See page 37 or
page 45.
Incorrect press wheel depth setting
Adjust T-handle. See page 53.
Opener spring pressure too low or too
high
Reduce opener spring pressure.
Problem
Cause
Solution