Troubleshooting

See also:
Lift Lock Troubleshooting” on page 105,
Brake Troubleshooting (Option)” on page 106 and
Troubleshooting and Alarms” topic in DICKEY-john

®

Air Cart Control manual.

General Troubleshooting

Problem

Causes

Solutions

No material flow
(all rows)

Tire problems at contact drive

Check transport and contact tire sizes and
inflation (page 152).

Broken or removed chain(s) in drive system

Check chains against “Chain Routing” on
page 154.

Removed final rate Range gear(s); for
example, single hopper operation with
incorrect meter disabled

Re-install gear(s) per seed rate chart and
calibration for affected meter.

Variable rate gearbox set to zero, or too low

Re-set gearbox per calibration.

Empty hopper

Load material.

Meter in use clogged

Clean-out meter (page 114).

Fan speed too low

Check pulses-per-rev setting for fan in seed
monitor (page 167). Increase fan speed to
recommended range (page 87).

Fan running backward

Reverse fan circuit hoses at hitch.

No material flow
(multiple rows)

Primary seed hose blocked

Check seed hoses for kinks, congealed
materials at low spots, nests and pests.

Tower inlet or turret blocked

Clear blockage.

No material flow
(one or two rows)

Seed tube blocked at row

Inspect and clear seed tube.

Tower port blocked for affected row

Disassemble distribution ring and clear
blockage.

False alarm - seed tube sensor
disconnected or failed

Run monitor self-test. Swap sensor with a
working row to verify failure. Replace sensor.

Material is flowing, but
is not detected by seed
monitor

This is normal during the first few meters/feet
of planting, as it takes some time for material
to reach rows.

Lower openers 3m/10ft before planting is to
begin. Monitor does not check for blockage
during first 5 seconds.

Lift switch mis-adjusted, failed or mis-wired.

Check, adjust or replace switch (page 117).

Seed monitor disconnected at hitch

Connect seed monitor.

Planting too little
(some rows)

Partial blockage in meter chamber, seed
hoses, towers, seed tubes

Treat as blockage. See “No material flow
(multiple rows)
” on page 102 and “No
material flow (one or two rows)
” on
page 102.