Seed Meter Final Drive Range

Refer to Figure 59 (which depicts the range gears with guard
removed - do not operate without guards)
The meter flute shaft

is driven by the agitator shaft

through a pair of interchangeable gears

,

. The

positioning of these gears creates two final drive ranges.

Each Seed Rate Chart is based on a specific Final Drive
Range. The Ranges are:

“High” range, which is used for larger seeds and

higher seeding rates

“Low” range, which is used for smaller seeds and

lower seeding rates

The meter shafts are DRIVING” and “DRIVEN”.
The “DRIVING” shaft is the upper (agitator) shaft.
The “DRIVEN” shaft is the lower (flute) shaft.

Refer to the Seed Rate Chart (or Fertilizer Rate chart),
the table at right, and Figure 59 for setting the seed
meter final drive range.

1.

Remove the nut and bolt (

, not visible) securing the

application rate sensor

to the restraining straps at

the meter sensor mount.

2.

Loosen the thumbscrew

.

3.

Remove the pins

from both shafts. Move the rpm

sensor clear of the flute shaft.

4.

Remove and position the gears as shown in the table
at right.

5.

Secure the DRIVING gear on the agitator shaft with
a pin.

6.

Secure the DRIVEN gear with the rpm sensor and a
pin.

7.

Use the thumbscrew to eliminate any rotational play
in the sensor-to-shaft coupling.

8.

Using the nut and bolt, secure the rpm sensor to the
restraining straps at the meter sensor mount.

Disable a Seed Meter
To avoid operating a meter:

1.

Remove a final range gear and leave it off.

2.

Set the variable rate gearbox to zero.

These steps are recommended even when the unused
hopper is empty, to:

• reduce gearbox and meter wear

• during calibration, to avoid clogging air tubes at the

meter not under test, and;

• avoid metering undesired material in the field.

Figure 59

High Final Drive Range

26368

FINAL DRIVE

RANGE

DRIVING

DRIVEN

LOW RANGE

17 Tooth Small

54 Tooth Large

HIGH RANGE

54 Tooth Large

17 Tooth Small

2

1

3

4

DRIVING

DRIVEN

7

8

5

6

8

1

2

3

4

5

6

7

8

Advertising
This manual is related to the following products: