Dismount Rear Vantage I Coulters

This applies only to kit 407-907A and three-coulter
configurations. For single-coulter configurations, skip to
Install Liquid Coulter” on page 183.

15. Using a grease pencil, note the locations of any

coulters using offset shanks.

Refer to Figure 103

Possible Agricultural Chemical Hazard:
Wear chemical gloves while handling disconnected drop lines.
Hose may contain residual amounts of chemical fluids. Consult
MSDS

a

for material most recently applied.

16. At each rear coulter pivot, disconnect the tubing

from the grease bank. Use a cable tie to secure all
but the left-most row’s grease bank tubing to a U-bolt
at the front coulter clamp.

17. If installed, disconnect any fertilizer drop lines

at

rear coulters. Disconnect at both the clamp

and at

the boom nozzle.

Refer to Figure 104
18. Replace nozzles

or

with caps at each

disconnected nozzle, except the left-most nozzle.

19. At the left-most nozzle, adapt it for half rate:

If using orifice plates, replace the existing plate
with a smaller size, having a port area of

1

2

, or

slightly larger than

1

2

of the port area of the existing

plate. See page 101 for a table of plates and ports.

If using VeriFlow nozzles, remove the:

829-143C NOZZLE HI-VERIFLOW1

(GRN/YEL)

and replace it with a:

829-144C NOZZLE VERIFLOW1

(BLU)

a. Material Safety Data Sheet

Figure 103

Drop Line and Grease Connections

32028

51

32

L41

L41

Figure 104

Fertilizer Nozzle Parts