11. Opening this bleed valve WILL release the

substantial amount of liquid NH

3

presently trapped in

the hose, most likely as a spray. Open the valve very
slowly, just until some fluid appears. Leave the valve
just slightly open.

12. Walk away, up-wind. Stay away until the release

concludes. Carefully open bleed valve completely to
confirm hose is discharged. For dual-cooler, repeat
step 9 through step 12 for the other hose.

13. Close all breakaway bleed valves (

x and

),

and any nurse tank hose valves

. Disconnect the

nurse tank half of the breakaway coupler at the
Acme coupler

.

14. Correct the cause of breakaway, only if trivial to do in

the field.

15. Consult the breakaway manual for re-coupling

instructions.

Before Re-connection: Elevated Exposure Hazard:
Exercise extreme care. Even if the nurse tank is undamaged,
sound and upright, a breakaway event is not a normal re-hitch
situation. A substantial NH

3

bleed is required that WILL

release a flow of liquid anhydrous ammonia under pressure.
If the wind is calm or light, do not attempt to bleed the nurse
tank hose(s).
Your field PPE

a

is not sufficient.

a. PPE: Personal Protective Equipment