John Deere stx38 User Manual

Page 130

Advertising
background image

4 - 46

3/21/97

CIRCUIT OPERATION AND DIAGNOSIS

ELECTRICAL

CHARGING CIRCUIT DIAGNOSIS STX30 & STX38 (SN —210000)

Test Conditions:

• Park brake engaged

• Engine running at fast idle

• Transaxle in neutral

• Meter negative (-) lead on battery negative (-)

• Regulator/rectifier connector disconnected

• Meter positive (+) lead on numbered test point

• Key switch in run position

Test/Check Point

Normal

If Not Normal

1. Battery positive terminal.

11.8—13.2 volts

Test battery

2. Regulator/rectifier connector.

Minimum unregulated voltage
output—28 VAC.

Check flywheel magnets, if OK
replace stator.

Test Conditions:

• Regulator/rectifier connector connected

Test/Check Point

Normal

If Not Normal

3. Regulator/rectifier center

terminal.

Battery voltage

Check battery positive cable
connections, and 210 red wires.

4. Regulator/rectifier wire.

Minimum regulated output—
13 amps at 12.2—14.7 volts
Voltage must stay below 14.7 volts.

Replace regulator/rectifier.