ELECTRICAL

CIRCUIT OPERATION AND DIAGNOSIS

4 - 50

3/21/97

CHARGING CIRCUIT DIAGNOSIS STX38 (SN 210001— ) & STX46

Test Conditions:

• Brake engaged

• Engine running at fast idle

• Regulator/rectifier connector disconnected

• Meter negative (-) lead on battery negative (-)

terminal

• Key switch in run position

• Meter positive (+) lead on numbered test point

Test/Check Point

Normal

If Not Normal

1. Battery positive terminal .

11.8-13.2 volts

Test battery

2. Regulator/rectifier connector

(between white wires).

Minimum unregulated voltage output
— 28 VAC.

Check flywheel magnets, if OK
replace stator.

Test Conditions:

• Regulator/rectifier connector connected

Test/Check Point

Normal

If Not Normal

3. Regulator/rectifier center

terminal (black wire).

Battery voltage

Check battery positive cable
connections, and 220 red wire.

4. Regulator/rectifier black wire.

Minimum regulated output—
13 amps at 12.2—14.7 volts.
Voltage must stay below 14.7 volts.

Replace regulator/rectifier .
Replace regulator/rectifier.