Error indicators, Troubleshooting – Casio XJ-350 User Manual

Page 111

Advertising
background image

111

Troubleshooting

Error Indicators

z “POWER” in the following table stands for the “POWER/STANDBY” indicator.
z “ ” in the “Alert” column indicates that the projector will emit four long beeps when an

error occurs. “

U” in the “Alert” column indicates that the projector will emit two short

beeps when an error occurs. Note that alert tones sound only when “On” is specified for
“Option Settings

J Alert Tones”.

z When an error occurs, wait until cool down is complete and the fan stops before

unplugging the AC power cord. If you unplug the AC power cord while the fan is still
operate, and error may occur when you plug the AC power cord back in.

Indicator

Alert

Description

POWER : Amber flashing

J

Red steady

An operational problem was caused by external
noise or some other factor. After confirming that the
POWER/STANDBY indicator is lit red (steady) and
that the fan has stopped, unplug the AC power
cord. After the indicator goes out, plug the AC
power cord back in and turn on the projector again.
If the error occurs again when you turn power back
on, contact your retailer or nearest authorized
CASIO Service Center.

TEMP

: Red steady

POWER : Amber flashing

J

Red steady

There is some problem with the fan.
After confirming that the POWER/STANDBY indicator
is lit red (steady) and that the fan has stopped,
unplug the AC power cord. After the indicator goes
out, plug the AC power cord back in and turn on
the projector again. If the error occurs again when
you turn power back on, contact your retailer or
nearest authorized CASIO Service Center.

TEMP

: Red flashing

(0.5-second interval)

POWER : Amber flashing

J

Red steady

Power has turned off automatically due to internal
overheating. Perform the following steps.

1

After confirming that the POWER/STANDBY
indicator is lit red, unplug the AC power cord
and wait for about 60 minutes to allow the
projector to cool down.

2

Check for any blocking of the projector’s intake
vents and exhaust vents, and make sure that
there is sufficient space around the projector.
) “Setup Precautions” (page 30).

3

Plug the AC power cord back in, and turn on
the projector again.

TEMP

: Red flashing

(1-second interval)

POWER : Amber flashing

J

Red steady

Power has turned off automatically due to a lamp
problem.
After confirming that the POWER/STANDBY indicator
is lit red, unplug the AC power cord, then plug it
back in and turn on the projector again. If this does
not correct the problem, wait for the projector to
cool down and then check the lamp cartridge for
damage. If there is nothing wrong with the lamp
cartridge, take it to your retailer or nearest
authorized CASIO Service Center.

TEMP

: Red flashing

(0.5-second interval)

LAMP

: Red flashing

(0.5-second interval)

Advertising