Carrier 50PG03-16 User Manual

Page 21

Advertising
background image

21

Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet

UNIT

50PG

NOMINAL

POWER

SUPPLY

VOLTS-PH-HZ

VOLTAGE

RANGE

COMPRESSOR

(EA)

OFM

FLA

IFM
FLA

POWER

EXHAUST

FLA

IFM

TYPE

ELECTRIC

HEAT

POWER

SUPPLY

CRSINGLE

PART

NO.

(NOTE3)

DISCONNECT

SIZE

WIRING

FIG.

NO.

MIN

MA

X

RLA

LRA

CRHEATER

PART

NO.

FLA

NOMINAL

KW*

MCA

MOCP†

FLA

LRA

03

208/230-1-60

187

253

12.8

60

0.9

4.9

Ċ

Low

Ċ

Ċ

Ċ/Ċ

27.8/27.8

30/30

Ċ

27/27

78/78

Ċ

200A00

10.8/12.5

2.3/3.0

27.8/27.8

30/30

028A00

27/27

78/78

13

201A00

17.3/20.0

3.8/5.0

32.8/36.1

35/40

028A00

31/34

78/78

13

202A00

26.0/30.0

5.6/7.5

43.6/48.6

45/50

028A00

41/46

78/78

13

203A00

34.7/40.0

7.5/10.0

54.5/61.1

60/70

028A00

51/57

78/78

13

High

Ċ

Ċ

Ċ/Ċ

27.8/27.8

30/30

Ċ

27/27

78/78

Ċ

200A00

10.8/12.5

2.3/3.0

27.8/27.8

30/30

028A00

27/27

78/78

13

201A00

17.3/20.0

3.8/5.0

32.8/36.1

35/40

028A00

31/34

78/78

13

202A00

26.0/30.0

5.6/7.5

43.6/48.6

45/50

028A00

41/46

78/78

13

203A00

34.7/40.0

7.5/10.0

54.5/61.1

60/70

028A00

51/57

78/78

13

1.4

Low

Ċ

Ċ

Ċ/Ċ

29.2/29.2

40/40

Ċ

29/29

80/80

Ċ

200A00

10.8/12.5

2.3/3.0

29.2/29.2

40/40

028A00

29/29

80/80

13

201A00

17.3/20.0

3.8/ 5.0

34.5/37.9

40/40

028A00

33/36

80/80

13

202A00

26.0/30.0

5.6/ 7.5

45.4/50.4

50/60

028A00

43/47

80/80

13

203A00

34.7/40.0

7.5/10.0

56.2/62.9

60/70

028A00

53/59

80/80

13

High

Ċ

Ċ

Ċ/Ċ

29.2/29.2

40/40

Ċ

29/29

80/80

Ċ

200A00

10.8/12.5

2.3/ 3.0

29.2/29.2

40/40

028A00

29/29

80/80

13

201A00

17.3/20.0

3.8/ 5.0

34.5/37.9

40/40

028A00

33/36

80/80

13

202A00

26.0/30.0

5.6/ 7.5

45.4/50.4

50/60

028A00

43/47

80/80

13

203A00

34.7/40.0

7.5/10.0

56.2/62.9

60/70

028A00

53/59

80/80

13

04

208/230-1-60

187

253

15.4

83

0.9

4.9

Ċ

Low

Ċ

Ċ

Ċ/Ċ

31.0/31.0

45/45

Ċ

30/30

101/101

Ċ

200A00

10.8/12.5

2.3/ 3.0

31.0/31.0

45/45

028A00

30/30

101/101

13

201A00

17.3/20.0

3.8/ 5.0

32.8/36.1

45/45

028A00

31/34

101/101

13

202A00

26.0/30.0

5.6/ 7.5

43.6/48.6

45/50

028A00

41/46

101/101

13

203A00

34.7/40.0

7.5/10.0

54.5/61.1

60/70

028A00

51/57

101/101

13

204A00

52.0/60.0

11.3/15.0

76.1/86.1

80/90

029A00

71/80

101/101

14

High

Ċ

Ċ

Ċ/Ċ

31.0/31.0

45/45

Ċ

30/30

101/101

Ċ

200A00

10.8/12.5

2.3/ 3.0

31.0/31.0

45/45

028A00

30/30

101/101

13

201A00

17.3/20.0

3.8/ 5.0

32.8/36.1

45/45

028A00

31/34

101/101

13

202A00

26.0/30.0

5.6/ 7.5

43.6/48.6

45/50

028A00

41/46

101/101

13

203A00

34.7/40.0

7.5/10.0

54.5/61.1

60/70

028A00

51/57

101/101

13

204A00

52.0/60.0

11.3/15.0

76.1/86.1

80/90

029A00

71/80

101/101

14

1.4

Low

Ċ

Ċ

Ċ/Ċ

32.4/32.4

45/45

Ċ

32/32

103/103

Ċ

200A00

10.8/12.5

2.3/ 3.0

32.4/32.4

45/45

028A00

32/32

103/103

13

201A00

17.3/20.0

3.8/ 5.0

34.5/37.9

45/45

028A00

33/36

103/103

13

202A00

26.0/30.0

5.6/ 7.5

45.4/50.4

50/60

028A00

43/47

103/103

13

203A00

34.7/40.0

7.5/10.0

56.2/62.9

60/70

028A00

53/59

103/103

13

204A00

52.0/60.0

11.3/15.0

77.9/87.9

80/90

029A00

73/82

103/103

14

High

Ċ

Ċ

Ċ/Ċ

32.4/32.4

45/45

Ċ

32/32

103/103

Ċ

200A00

10.8/12.5

2.3/ 3.0

32.4/32.4

45/45

028A00

32/32

103/103

13

201A00

17.3/20.0

3.8/ 5.0

34.5/37.9

45/45

028A00

33/36

103/103

13

202A00

26.0/30.0

5.6/ 7.5

45.4/50.4

50/60

028A00

43/47

103/103

13

203A00

34.7/40.0

7.5/10.0

56.2/62.9

60/70

028A00

53/59

103/103

13

204A00

52.0/60.0

11.3/15.0

77.9/87.9

80/90

029A00

73/82

103/103

14

208/230-3-60

187

253

11.5

77

0.9

4.9

Ċ

Low

Ċ

Ċ

Ċ/Ċ

25.0/25.0

30/30

Ċ

25/25

95/95

Ċ

207A00

6.3/ 7.2

2.3/ 3.0

25.0/25.0

30/30

030A00

25/25

95/95

15

208A00

10.0/11.5

3.8/ 5.0

25.0/26.0

30/30

030A00

25/25

95/95

15

209A00

15.0/17.3

5.6/ 7.5

30.9/33.2

35/35

030A00

28/31

95/95

15

210A00

20.0/23.1

7.5/10.0

37.2/40.4

40/45

030A00

34/38

95/95

15

211A00

30.0/34.6

11.3/15.0

49.7/54.9

50/60

030A00

46/51

95/95

15

High

Ċ

Ċ

Ċ/Ċ

25.0/25.0

30/30

Ċ

25/25

95/95

Ċ

207A00

6.3/ 7.2

2.3/ 3.0

25.0/25.0

30/30

030A00

25/25

95/95

15

208A00

10.0/11.5

3.8/ 5.0

25.0/26.0

30/30

030A00

25/25

95/95

15

209A00

15.0/17.3

5.6/ 7.5

30.9/33.2

35/35

030A00

28/31

95/95

15

210A00

20.0/23.1

7.5/10.0

37.2/40.4

40/45

030A00

34/38

95/95

15

211A00

30.0/34.6

11.3/15.0

49.7/54.9

50/60

030A00

46/51

95/95

15

LEGEND

FLA

− Full Load Amps

HACR − Heating, Air Conditioning and Refrigeration
IFM

− Indoor − Fan Motor

LRA

− Locked Rotor Amps

MCA

− Minimum Circuit Amps

MOCP − Maximum Overcurrent Protection
NEC

− National Electrical Code

OFM

− Outdoor−Fan Motor

RLA

− Rated Load Amps

*

Heater capacity (kW) is based on heater voltage of 208 v, 240 v, or 480 v. If power distribu-

tion voltage to unit varies from rated heater voltage, heater kW will vary accordingly.

Fuse or HACR circuit breaker.

NOTES:

1. In compliance with NEC requirements for multimotor and combination load equip-

ment (refer to NEC Articles 430 and 440), the overcurrent protective device for the
unit shall be fuse or HACR breaker.

2. Unbalanced 3-Phase Supply Voltage

Never operate a motor where a phase imbalance in supply voltage is greater than
2%.

Use the following formula to determine the percentage of voltage imbalance.

% Voltage Imbalance

= 100 x

max voltage deviation from average voltage

average voltage

Example: Supply voltage is 460-3-60

AB = 224 v
BC = 231 v
AC = 226 v
Average Voltage =

224 + 231 + 226
3

681
3

=

227

=

Determine maximum deviation from average voltage.

(AB) 227 – 223 = 3 v
(BC) 231 – 227 = 4 v
(AC) 227 – 226 = 1 v

Maximum deviation is 4 v.
Determine percent of voltage imbalance.

% Voltage Imbalance

= 100 x

4

227

= 1.76%

This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.

IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric
utility company immediately.

3. Single point kits CRSINGLE028A00 and CRSINGLE030A00 are not required if

field−supplied pressure connectors are used.

50PG03−16

Advertising