28

About Your System

Memory tests

terminated by

keystroke.

POST memory test was
terminated by pressing the
spacebar.

Information only.

MEMTEST lane

failure

detected on

x.

Invalid memory
configuration. Mismatched
memory modules are
installed.

Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module
Installation Guidelines" on
page 81.

Mirror mode

disabled. For

mirror mode,

DIMMs must be

installed in

pairs. Pairs must

be matched in

size and

geometry.

The memory configuration
does not match the setting in
BIOS. The BIOS setting has
been disabled.

Reconfigure the memory
modules for Memory
Mirroring mode. See
"System Memory" on
page 80.

No boot device

available.

Faulty or missing hard drive,
or hard drive subsystem, or
no bootable USB key
installed.

Use a bootable USB key or
hard drive. If the problem
persists, see
"Troubleshooting a USB
Device" on page 130 and
"Troubleshooting a Hard
Drive" on page 139.
See "Using the System Setup
Program and
UEFI Boot Manager" on
page 39 for information on
setting the order of boot
devices.

Message

Causes

Corrective Actions

book.book Page 28 Wednesday, May 12, 2010 9:26 PM