Fault tolerance features, Firmware upgrade, Hot swapping – Dell PERC 4/SI User Manual

Page 26

Advertising
background image

 

Firmware Upgrade

 

 

You can download the latest firmware from the Dell website and flash it to the firmware on the board. The Dell website offers a firmware flash that can be
executed from a DOS environment or one that can be launched from within the Microsoft Windows or Linux operating system. To upgrade the firmware on the
RAID controller perform the following instructions:

1.

 

Download the latest RAID controller firmware from the Dell website located at:

http://support.dell.com

.

 

2.

 

Use the unique instructions for each firmware update version that are posted on the Dell website to complete the firmware update process.

 

 

Fault Tolerance Features

 

Table 3

-4

lists the features that provide fault tolerance to prevent data loss in case of a failed drive.

 

 

Table 3-4. Fault Tolerance Features 

 

Hot Swapping

 

Hot swapping is the manual substitution of a replacement unit in a disk subsystem for a defective one, where the substitution can be performed while the
subsystem is running (performing its normal functions). The backplane and enclosure must support hot swap in order for the functionality to work.

 

 

Failed Drive Detection

 

WS 2003 Standard Server

 

Y

 

Y

 

Y

 

WS 2003 Web Server

 

Y

 

Y

 

Y

 

2003 Small Business Server (SBS)

 

Y

 

Y

 

Y

 

WS 2003 Enterprise Server

 

Y

 

Y

 

Y

 

W2K3 EM64T

 

N

 

Y

 

Y

 

RHEL v2.1 Update 3

 

Y

 

Y

 

Y

 

RHEL v3.0 Update 2 (EM64T)

 

N

 

Y

 

Y

 

RHEL v3.0 GOLD

 

Y

 

Y

 

Y

 

RHEL v3.0 Update 3 (32bit and EM64T)  N

 

Y

 

Y

 

RHEL 4.0 32-bit

 

Y

 

Y

 

Y

 

RHEL 4.0 EM64T

 

N

 

Y

 

Y

 

NetWare 5.1 SP8

 

Y

 

Y

 

Y

 

NetWare 6.5 SP3

 

Y

 

Y

 

Y

NOTICE:

Do not flash the RAID controller firmware while performing a background initialization or data consistency check as this can cause the

procedure to fail.

NOTE:

If you system does not have a floppy disk drive, download the firmware update utility for Microsoft Windows or Linux. For systems running

Novell Netware that do not have a floppy drive; create the firmware update diskette on another system, then copy the contents of the floppy to a
bootable USB key or CD-ROM.

NOTE:

A reboot is required after the firmware update is complete.

Specification

Feature

 

Support for SMART

 

Yes

 

Support for Patrol Read

 

Yes

 

Drive failure detection

 

Automatic

 

Drive rebuild using hot spares

 

Automatic

 

Parity generation and checking

 

Yes

 

Battery backup for NVRAM to protect configuration data

 

Yes

 

Hot-swap manual replacement of a disk unit without bringing the system down  Yes

NOTE:

A backplane or enclosure must support hot swapping in order for the RAID controller to support hot swapping.