Rebuilding failed hard drives – Dell PERC 4/SI User Manual

Page 46

Advertising
background image

l

 

Using the Objects—> Physical Drive menu.

 

<F4> Key

 

When you select any configuration option, a list of all physical devices connected to the current controller appears. Perform the following steps to designate a
drive as a hot spare:

1.

 

On the Management Menu select Configure, then a configuration option.

2.

 

Press the arrow keys to highlight a hard drive that displays as READY.

3.

 

Press <F4> to designate the drive as a hot spare.

4.

 

Click YES to make the hot spare.

 

The drive displays as HOTSP.

5.

 

Save the configuration.

 

Objects Menu

1.

 

On the Management Menu select Objects—> Physical Drive.

 

A physical drive selection screen appears.

2.

 

Select a hard drive in the READY state and press <Enter> to display the action menu for the drive.

3.

 

Press the arrow keys to select Make HotSpare and press <Enter>.

 

The selected drive displays as HOTSP.

 

Rebuilding Failed Hard Drives

 

If a hard drive fails in an array that is configured as a RAID 1, 5, 10, or 50 logical drive, you can recover the lost data by rebuilding the drive with another drive
or drives. You can manually rebuild one drive or a group of drives using the manual rebuild procedures in this section.

 

If a system is rebooted during a rebuild operation, it is possible for the rebuild to restart from 0 percent.

 

 

 

Rebuild Types

 

Table 4

-13

describes automatic and manual rebuilds.

 

 

Table 4-13. Rebuild Types

 

NOTE:

An array may take longer to rebuild when under high stress; for example, when there is one rebuild I/O operation to five host I/O operations.

NOTE:

In a clustering environment, if a node fails during a rebuild, the rebuild is re-started by another node. The rebuild on the second mode starts at

zero percent.

Type

Description

 

Automatic

Rebuild

 

If you have configured hot spares, the RAID controller automatically tries to use them to rebuild failed disks. Select Objects—> Physical

Drive to display the list of physical drives while a rebuild is in progress. The hot spare drive changes to REBLD A[array number]-[drive
number
], indicating the hard drive is being replaced by the hot spare. For example, REBLD A01-02 indicates that the data is being rebuilt on
hard drive 2 in array 1.

 

Manual

Rebuild

 

Manual rebuild is necessary if no hot spares with enough capacity to rebuild the failed drives are available.You must insert a drive with

enough storage into the subsystem before rebuilding the failed drive.