Dell PERC 4/SI User Manual

Page 33

Advertising
background image

 

Patrol Read Options

 

Table 4

-4

describes the Patrol Read Options submenu. See

Patrol Read

for detailed information about the Patrol Read.

 

 

Table 4-4. Patrol Read Options Menu 

 

Logical Drive

 

Select Objects→ Logical Drive to select a logical drive and to perform the actions listed in

Table 4

-5

.

 

 

Table 4-5. Logical Drive Menu Options 

 

Physical Drive

 

Select Objects→ Physical Drive to select a physical device and to perform the operations listed in the table below. The physical drives in the computer are
listed. Move the cursor to the desired device and press <Enter> to display the screen.

 

Table 4

-6

displays the operations you can perform on the physical drives.

 

 

Table 4-6. Physical Drive Menu Options 

 BIOS Echoes Messages:

When set to On (the default), all controller BIOS messages display during bootup.

 BIOS Configuration Autoselection:

Use this option if there is a mismatch between configuration data in the drives and NVRAM, so you

can select a method to resolve it. The options are NVRAM, Disk, and User. The default is User.

 

Patrol Read

Options

 

Patrol Read involves the review of your system for possible hard drive errors that could lead to drive failure, then action to correct

errors. The goal is to protect data integrity by detecting physical drive failure before the failure can damage data. Patrol Read occurs only
when the controller is idle for a defined period of time and no other background tasks are active.

 

Patrol Read Options gives you the ability to start and stop Patrol Reads, display Patrol Read status, and set the Patrol Read mode. See

Patrol Read

for detailed information about the Patrol Read.

Option

Description

 

Patrol Read Mode  Use this option to set Patrol Read for manual operation (user-initiated) or automatic operation, or to disable Patrol Read.

 

Patrol Read

Status

 

Displays the number of iterations completed, the current state of the Patrol Read (active or stopped), and the schedule for the next

execution of Patrol Read.

 

Patrol Read

Control

 

Use this option to start or stop Patrol Read.

Option

Description

 

Initialize

 

Initializes the selected logical drive. Do this for every logical drive that is configured.

 

Check Consistency

 

Verifies the correctness of the redundancy data in the selected logical drive. This option is available only if RAID level 1, 5, 10, or 50 is

used. The RAID controller automatically corrects any differences found in the data.

 

View/Update

Parameters

 

Displays the properties of the selected logical drive. You can modify the cache write policy, read policy, and the input/output (I/O)

policy from this menu.

Option

Description

 

Rebuild

 

Rebuilds the selected physical drive.

 

Rebuild

 

Select this option to rebuild a failed hard disk drive.

 

Clear

 

Select this option to clear the data from SCSI drives.

 

Force Online

 

Changes the state of the selected hard drive to online.

 

Force Offline/Remove

HSP

 

Changes the state of the selected hard drive to offline.

 

Make HotSpare

 

Designates the selected hard drive as a hot spare.

 

View Drive

Information

 

Displays the drive properties for the selected physical device.

Advertising
This manual is related to the following products: