Select Objects→ Channel to select a SCSI channel on the currently selected controller. After you select a channel, press <Enter> to display the options for
that channel.

Table 4

-7

describes the SCSI channel menu options.

 

 

Table 4-7. SCSI Channel Menu Options 

 

Clear Menu

 

You can clear the data from SCSI drives using the configuration utilities. See

Clearing Physical Drives

for more information and the procedure for clearing the

data.

 

Rebuild Menu

 

Select Rebuild from the Management Menu to rebuild one or more failed physical drives. See

Rebuilding Failed Hard Drives

for more information and the

procedure to perform a drive rebuild.

 

Check Consistency Menu

 

Select Check Consistency to verify the redundancy data in logical drives that use RAID levels 1, 5, 10, and 50. See

Checking Data Consistency

for more

information and the procedure to perform a check consistency.

 

Reconstruct Menu

 

Select Reconstruct to change the RAID level of an array or add a physical drive to an existing array. RAID level migration changes the array from one RAID
level to another. Online capacity expansion is the addition of hard disk drives to increase storage capacity.

 

Device Management

 

Device Management Functions

 

This section deals with device management, which means management of the physical devices. This includes the physical drives, hot spares, drive migration,
and drive roaming. See

Drive Roaming

and

Drive Migration

for details about these procedures.

 

 

View Rebuild Progress  Indicates how much of the rebuild has been completed.

 

Set Write Cache

 

Select this option to enable or disable write cache on this device. See

Logical Drive Parameters and Descriptions

in this section for

more information about write cache policy.

 

Transfer Speed Option  Selects the speed at which data is transferred. Displays a menu that contains the options Negotiation=Wide, and Set Transfer

Speed. The maximum transfer speed is 320 M.

Option

Description

 

Termination State

 

When set to enabled, the RAID controller is terminated. When set to disabled, it is not terminated. Normally, you do not need to

change this setting; the RAID controller automatically sets this option.

 

Enable Auto

Termination

 

Select this option to enable or disable auto termination of the SCSI bus.

 

SCSI Transfer Rate  Used to select the SCSI transfer rate. The options are Fast, Ultra, Ultra-2, and 160M.

 

NOTE:

The disk transfer rate is set for each disk, while the SCSI channel transfer rate controls the speed of the bus. No matter how

fast you set the disk transfer rate, the speed depends on the SCSI channel transfer rate.