Raid controller specifications, Scsi bus, Scsi termination – Dell PERC 4/SI User Manual

Page 27: Scsi firmware

Advertising
background image

 

The firmware automatically detects and rebuilds failed drives. This can be done transparently with hot spares.

 

RAID Controller Specifications

 

Table 3

-5

lists the RAID controller specifications.

 

 

Table 3-5. RAID Controller Specifications 

 

SCSI Bus

 

The RAID adapter controls hard drives using Ultra320 SCSI buses (channels) over which the system transfers data in Ultra320 SCSI mode. The PERC 4/Si and
4e/Si controllers control one SCSI channel, while the PERC 4/Di and 4e/Di controls two. The SCSI channel supports up to 15 wide or seven non-wide SCSI
devices at speeds up to 320 MB/sec.

 

SCSI Termination

 

The RAID controller uses active termination on the SCSI bus conforming to SCSI-3 and SCSI SPI-4 specifications. Termination enable/disable is automatic
through cable detection.

 

SCSI Firmware

 

The RAID controller firmware handles all RAID and SCSI command processing and supports the features described in

Table 3

-6

.

 

Parameter

PERC 4/Di/Si

PERC 4e/Di/Si

 

Processor

 

Intel

®

i303 64-bit RISC processor @ 100 MHz

 

Intel

®

IOP332 I/O processor with Intel XScale

Technology

 

Bus type

 

PCI Rev. 2.2

 

PCI Express Rev. 1.0a

 

PCI Express controller

 

Intel i303

 

Intel i303

 

Bus data transfer rate

 

Up to 532 MB/sec at 64/66 MHz

 

Up to 4 GB/sec

 

Cache memory size

 

128 MB

 

256 MB (DDR2)

 

Cache function

 

Write-back, Write-through, Adaptive read-

ahead, Non read-ahead, Read-ahead

 

Write-back, Write-through, Adaptive read-

ahead, Non read-ahead, Read-ahead

 

Flashable firmware

 

1 MB x 8 flash ROM

 4 MB × 16 flash ROM

 

Nonvolatile random access memory (NVRAM)

 32 KB × 8 for storing RAID configuration

 32 KB × 8 for storing RAID configuration

 

SCSI data transfer rate

 

Up to 320 MB/sec per channel

 

Up to 320 MB/sec per channel

 

SCSI bus

 

LVD or single-ended

 

LVD

 

SCSI termination

 

Active

 

Active

 

Termination disable

 

Automatic through cable and device detection

 

Automatic through cable and device detection

 

Devices per SCSI channel

 

Up to 15 wide or seven narrow SCSI devices

 

Up to 15 wide or seven narrow SCSI devices

 

SCSI device types

 

Synchronous or asynchronous

 

Synchronous or asynchronous

 

RAID levels supported

 

0, 1, 5, 10, and 50

 

0, 1, 5, 10, and 50

 

Multiple logical drives/arrays per controller

 

Up to 40 logical drives per controller

 

Up to 40 logical drives per controller

 

Online capacity expansion

 

Yes

 

Yes

 

Dedicated and pool hot spare

 

Yes

 

Yes

 

Hot swap devices supported

 

Yes

 

Yes

 

Non-disk devices supported

 

NOTE:

PERC 4/Di/Si and 4e/Di/Si do not support any

non- disk devices except backplanes.

 

Yes

 

Yes

 

Mixed capacity hard drives

 

Yes

 

Yes

Advertising