Dell PowerVault DR2000v User Manual

Page 167

Advertising
background image

Alert Message

Description/Meaning or Action

Fan <

number

> is missing.

Attach or replace the designated missing cooling fan.

Abnormal network errors detected on Network Interface
Controller <

number

>.

The Network Interface Controller errors could be caused
by network congestion or by packet errors.

•

Check your network. If that does not resolve the

problem, then replace the NIC.

•

If the NIC is embedded, the DR Series system

appliance requires service.

Network Interface Controller is missing.

•

Remove and reinsert the NIC.

•

If this does not resolve the problem, replace the NIC.

Network Interface Controller <

name

> is disconnected.

Connect it to a network and/or check your network
switches or routers for any network connectivity issues.

Network Interface Controller <

name

> is disabled.

Enable the port on the designated NIC.

Network Interface Controller <

name

> driver is bad.

Upgrade the DR Series system appliance (in the Software
Upgrade page, and click Start Upgrade).

CPU <

name

> failed.

Replace the designated failed processor.

CPU <

name

> is missing.

Reinsert or replace the designated missing processor.

DIMM <

name

> failed.

Replace the designated failed DIMM (Dual In-line Memory
Module) device.

DIMM <

name

> is missing.

•

Reinsert or replace the designated DIMM device.

•

The memory capacity of the storage appliance is

below the minimum required for correct operation.

•

The storage appliance requires service.

Temperature probe <

name

> failed.

The storage appliance requires service.

Voltage probe <

name

> failed.

The storage appliance requires service.

Temperature probes have recorded temperatures in the
failed range.

•

Check the Events page in the DR Series system for

specific temperature events and the location of the

temperature probes.

•

Check the data center air conditioning, ventilation, and

internal system cooling fans for any problems.

•

Ensure there is proper air flow through the storage

appliance, and as needed, clean the cooling vents.

Voltage probes have recorded readings in the failed
range.

•

Check the Events page in the DR Series system for

specific voltage events and the location of the voltage

probes.

•

Check the power supplies. If there are no issues with

the power supplies, have a service technician check

the DR Series system appliance to see if it requires any

servicing.

Storage Controller <

number

> failed.

Replace the RAID controller in the DR Series system.

167