MIBs Implemented

SYNTAX Gauge

ACCESS read-only

STATUS mandatory

DESCRIPTION "Health Check interval in minutes."

::= { bladeEntry 7 }

bladeFWRev OBJECT-TYPE

SYNTAX DisplayString (SIZE (0..64))

ACCESS read-only

STATUS mandatory

DESCRIPTION "Blade Firmware Revision information."

::= { bladeEntry 8 }

bladeSerialNumber OBJECT-TYPE

SYNTAX DisplayString (SIZE (0..64))

ACCESS read-only

STATUS mandatory

DESCRIPTION "Blade Serial Number."

::= { bladeEntry 9 }

bladeEVPSEnabled OBJECT-TYPE

SYNTAX INTEGER

ACCESS read-only

STATUS mandatory

DESCRIPTION "Bit 0: EVPS active if 1, inactive if 0

Bit 1: EVPS licensed if 1, unlicensed if 0"

::= { bladeEntry 10 }

bladeMaxHostLun OBJECT-TYPE -- C.R. 2370

SYNTAX INTEGER

ACCESS read-only

STATUS mandatory

DESCRIPTION "The number of devices one host can see"

::= { bladeEntry 11 }

bladeState OBJECT-TYPE

SYNTAX BladeState

ACCESS read-only