Dell PowerVault ML6000 User Manual

Page 135

Advertising
background image

Dell PowerVault ML6000

Basic SNMP Reference Guide

129

DESCRIPTION "The physical FC port Index. The available ports are 1,2."

::= { blHPFPhysicalEntry 1 }

blHPFPhysicalPortFailureType OBJECT-TYPE

SYNTAX FcHPFPortFailType

ACCESS read-only

STATUS mandatory

DESCRIPTION "If this physical port failed, this field provides the

type of failure.Values 0 = None, 1 = Link Down

2 = Link Error"

::= { blHPFPhysicalEntry 2 }

blHPFPhysicalPortCurrentState OBJECT-TYPE

SYNTAX FcHPFPortState

ACCESS read-only

STATUS mandatory

DESCRIPTION "The current state of this physical port. The values

0 = Online, 1 = Offline"

::= { blHPFPhysicalEntry 3 }

blHPFPhysicalPortIntervention OBJECT-TYPE

SYNTAX Boolean

ACCESS read-only

STATUS mandatory

DESCRIPTION "Does this physical port require intervention? Values

1 = true, 2 = false"

::= { blHPFPhysicalEntry 4 }

-- end blade additions

--

-- NotificationOnlyData is a way to get the payload data across without

-- relating it to other MIB OID's, a dummy OID

faultyLibLocation OBJECT-TYPE

SYNTAX DisplayString

MAX-ACCESS accessible-for-notify

STATUS current

DESCRIPTION

Advertising