System messages – Dell POWEREDGE M915 User Manual

Page 115

Advertising
background image

About Your System

115

System Messages

Table 1-27 lists the system messages that can occur and the probable cause

and corrective action for each message.

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

NOTE:

If you receive a system message that is not listed in Table 1-27, check the

documentation for the application that is running when the message appears, or the

operating system's documentation for an explanation of the message and

recommended action.

Table 1-27. Blade Messages

Message

Causes

Corrective Actions

Failed to allocate
sufficient blade
power. Check PCIe
card power usage
is within limits.

This error occurs when

BIOS does not receive a

'Power Granted' status for

the blade from iDRAC

during POST within a

certain timeout period.

POST halts when this

error occurs.

NOTE:

Applicable to M610x

only.

A common case that can

cause this error is if the PCIe

card power allocation

specified in the iDRAC GUI

is too high and exceeds

system limits.

Warning: PCIe
expansion riser
failed to
initialize at
maximum link width
(x16). Performance
will be degraded.

This warning occurs if the

PCIe expansion riser

initializes at a slower link

capacity than the

maximum resulting in

degraded performance.

NOTE:

Applicable to M610x

only.

The common cause of this

condition is incorrect

cabling. See "Expansion

Cards and Expansion-Card

Riser (PowerEdge M610x

Only)" on page 235.