Dell POWEREDGE M915 User Manual

Page 50

Advertising
background image

50

About Your System

The CMC supports setting an optional enclosure Maximum Power

Limit, which either alerts or takes actions, such as throttling server

modules and/or preventing the power up of new blades to keep the

enclosure under the defined maximum power limit.

The CMC monitors and automatically controls cooling fans based on

actual ambient and internal temperature measurements.

The CMC provides comprehensive enclosure inventory and

status/error reporting.

• The CMC provides a mechanism for centralized configuration of the

following:

The M1000e enclosure’s network and security settings

Power redundancy and power ceiling settings

I/O switches and iDRAC network settings

First boot device on the server blades

The CMC checks I/O fabric consistency between the I/O modules and

blades and disables components if necessary to protect the system

hardware.

User access security.

The CMC has two Ethernet ports: Gb1 is used to connect to the external

management network. The connector labeled STK ("stack") allows CMCs in

adjacent enclosures to be daisy-chained. A 24-port Ethernet switch provides

internal communication between the iDRAC on each blade, I/O modules,

optional KVM, and optional second, redundant CMC.

NOTE:

The 24-port Ethernet switch is reserved for internal communication

between the iDRAC on the blades to the CMC and the external management

network. If two CMCs are installed, the heartbeat for CMC redundancy is also

present and CMC redundancy is supported over this internal network. This internal

network is outside the data path from host LOMs and the mezzanine cards in the

blades.

At least one CMC must be installed in the primary CMC bay (see

Figure 1-22) for the system to power up. If a second, optional CMC module is

installed, failover protection and hot-plug replacement is available.
See the latest Dell Chassis Management Controller User's Guide at

support.dell.com/manuals for complete instructions on how to set up and

operate the CMC module.

Advertising