Dell POWEREDGE M915 User Manual

Page 130

Advertising
background image

130

About Your System

Read fault.

Faulty diskette, diskette

drive, or optical drive.

Replace the diskette. Ensure

that the drive cable is

properly connected. See

"Troubleshooting USB

Devices" on page 312 or

"Troubleshooting Hard

Drives" on page 320 for the

appropriate drive(s)

installed in your system.

Remote
Configuration
update attempt
failed.

Blade could not

implement Remote

Configuration request.

Retry Remote

Configuration.

Sector not found.
Seek error.
Seek operation
failed.

Faulty diskette or hard

drive.

Replace the diskette. If the

problem persists, see

"Troubleshooting Hard

Drives" on page 320 for the

appropriate drive installed in

your system.

Shutdown failure.

Shutdown test failure.

Ensure that all memory

modules are properly

installed. See

"Troubleshooting Blade

Memory" on page 319. If the

problem persists, see

"Getting Help" on page 361.

Spare bank
enabled.

Memory sparing enabled. Information only.

System service
update required.

The iDRAC6 Enterprise

Card flash memory may be

corrupted.

Restore the flash memory

using the latest version on

ftp.dell.com or

support.dell.com. See the

iDRAC6 User’s Guide for

instructions on performing a

field replacement of the

flash memory.

Table 1-27. Blade Messages

(continued)

Message

Causes

Corrective Actions

Advertising