Associated target servers and power outlets – Dell KVM 1082DS User Manual

Page 71

Advertising
background image

Local and Remote Configuration

xxx

|

xxx

61

that power device: Name, Description, Status, Version, Sockets, Vendor Name,
Model, and Input Feeds.

If a target device is connected to a power control device outlet, you can turn on,
turn off or cycle (turn off, then turn on) the target device.

To turn on, turn off or power cycle a target device:

1

From the side navigation bar, click Ports - Power Devices to open the
Power Devices screen.

2

Click the name of the unit you wish to configure and select Outlet List.

3

Select the checkbox to the left of the outlet(s) that you wish to configure.

4

Click On, Off, or Cycle, as desired.

To delete offline power devices:

1

From the side navigation bar, click Ports - Power Devices to open the
Power Devices screen.

2

Click Delete Offline.

To change the minimum on time, off time or wake up state:

1

From the side navigation bar, click Ports - Power Devices to open the
Power Devices screen.

2

Click the name of the unit you wish to configure and select Outlets.

3

Click the outlet name that you wish to modify.

4

Use the drop-down windows to alter the desired settings and click Save.

Associated Target Servers and Power Outlets

In the OBWI Target List page, power control actions are selectable for a target
with linked outlets. Selecting the Ports - Power Devices tabs, and then clicking
on a device name will display the Device Settings, Device Firmware Upgrade,
and Outlet List tabs. Click the Outlet List tab to display the outlets linked with
a target device.