Dell PowerEdge RAID Controller 6i User Manual

Page 116

Advertising
background image

116

Troubleshooting

Physical disk removed:

Physical Disk {x.x.x}

Controller {x}, Connector

{x}

Device failed: Physical

Disk {x.x.x} Controller

{x}, Connector {x}".

These two messages appear in the event log
when you remove a drive. The first message
indicates that the disk was removed and the
second message indicates that the device has
failed. This feature is working as designed.

A storage component such as a physical disk or
an enclosure has failed. The failed component
might have been identified by the controller
while performing a task such as a rescan or a
check consistency.

Replace the failed component. You can identify
the failed dsik as its status displays a red

X

.

Perform a rescan after replacing the disk.

Battery is missing or the

battery could be fully

discharged. If battery is

connected and has been

allowed to charge for 30

minutes and this message

continues to appear, then

contact Technical Support

for assistance.

• The controller battery is missing or damaged.

• The controller battery is completely

discharged and needs to be charged for it to
become active. The battery must first be
charged, and then it is found by the system
several minutes later.

Table 7-1.

BIOS Errors and Warnings (continued)

Message

Meaning

Dell_PERC6.1_UG.book Page 116 Wednesday, April 15, 2009 4:18 PM