Dell PowerEdge RAID Controller 6i User Manual

Page 28

Advertising
background image

28

About PERC 6 and CERC 6i Controllers

When a controller detects a physical disk with a pre-existing configuration, it
flags the physical disk as foreign, and it generates an alert indicating that a
foreign disk was detected.

CAUTION:

Do not attempt disk roaming during RLM or CE. This causes loss of the

virtual disk.

Perform the following steps to use disk migration.

1 Turn off the system that contains the source controller.
2 Move the appropriate physical disks from the source controller to the

target controller.

The system with the target controller can be running while inserting the
physical disks.

The controller flags the inserted disks as foreign disks.

3 Use the Open Manage storage management application to import the

detected foreign configuration.

NOTE:

Ensure that all physical disks that are part of the virtual disk are migrated.

NOTE:

You can also use the controller BIOS configuration utility to migrate disks.

Compatibility With Virtual Disks Created on PERC 5 Controllers

Virtual disks that were created on the PERC 5 family of controllers can be
migrated to the PERC 6 and CERC 6i controllers without risking data or
configuration loss. Migrating virtual disks from PERC 6 and CERC 6i controllers
to PERC 5 is not supported.

NOTE:

For more information about compatibility, contact your Dell Technical

Support Representative.

Virtual disks that were created on the CERC 6/i controller or the PERC 5
family of controllers can be migrated to PERC 6.

Dell_PERC6.1_UG.book Page 28 Wednesday, April 15, 2009 4:18 PM