Fault tolerance features, Physical disk hot swapping – Dell PowerEdge RAID Controller 6i User Manual

Page 36

Advertising
background image

36

About PERC 6 and CERC 6i Controllers

Fault Tolerance Features

Table 3-3 lists the features that provide fault tolerance to prevent data loss in
case of a failed physical disk.

Physical Disk Hot Swapping

Hot swapping is the manual substitution of a replacement unit in a disk
subsystem for a defective one. The manual substitution can be performed while
the subsystem is performing its normal functions.

NOTE:

The system backplane or enclosure must support hot swapping in order for

the PERC 6 and CERC 6/i controllers to support hot swapping.

NOTE:

Ensure that SAS drives are replaced with SAS drives, and SATA drives are

replaced with SATA drives.

NOTE:

While swapping a disk, ensure that the new disk is of equal or greater

capacity than the disk that is being replaced.

Table 3-3.

Fault Tolerance Features

Specification

PERC

CERC

Support for SMART

Yes

Yes

Support for Patrol Read

Yes

Yes

Redundant path support

Yes

N/A

Physical disk failure detection

Automatic

Automatic

Physical disk rebuild using hot spares

Automatic

Automatic

Parity generation and checking (RAID 5, 50, 6, and
60 only)

Yes

N/A

Battery backup of controller cache to protect data Yes

a

N/A

Manual learn cycle mode for battery backup

Yes

N/A

Detection of batteries with low charge after
bootup

Yes

N/A

Hot-swap manual replacement of a physical disk
without reboot

Yes

Yes

a

The PERC 6/i adapter supports a BBU on selected systems only. For additional information, see
the documentation that was shipped with the system.

Dell_PERC6.1_UG.book Page 36 Wednesday, April 15, 2009 4:18 PM