Configuring Your Managed System

25

Baud Rate

This field sets the baud rate at which serial data is transferred by the BMC when SOL is active. The

choices are

Default IPMI, 9600 bps, 19.2 kbps, 38.4 kbps, 57.6 kbps, and 115.2 kbps. If Default

IPMI is selected, the baud rate used is the rate currently set for BIOS serial redirection. When SOL

is active, serial communication with the BMC always occurs with 8 data bits, no parity, 1 stop bit,

and RTS/CTS (hardware) flow control.

LAN Alert Configuration

See the System Software Guide on the Resource CD for information about configuring BMC LAN

alerts. Click

Next to move to the Serial Over LAN screen.

Configuring Your Managed System with Server Administrator

You can also configure the BMC options using Server Administrator Version 1.8.3. Server

Administrator is a one-to-one system management software program that must be installed on the

managed system. Once installed, Server Administrator can be remotely accessed from a

management station with a supported browser to perform BMC configuration tasks. See the Sever

Administrator User’s Guide for more information about installing and using the Server

Administrator.
You can configure the BMC settings from either the Server Administrator home page or from its

command line interface. Users must have Administrator privileges to access the BMC settings.

Users logged in with User or Power User group privileges can view the BMC information but

cannot change the settings.
See the Server Administrator Version 1.8.3 Command Line Interface User's Guide for information

about configuring the BMC from the command line.
When using Server Administrator, you can click

Help on the global navigation bar for more

detailed information about the specific window you are viewing. Server Administrator help is

available for all windows accessible to the user based on user privilege level and the specific

hardware and software groups that Server Administrator discovers on the managed system.

Configuring Your Managed System to Access its BMC

The Server Administrator Instrumentation Service allows you to manage Baseboard Management

Controller (BMC) features such as general BMC information, configuration of the LAN and serial

port, and BMC users. To use Server Administrator to configure the BMC on a managed system,

perform the following steps:

NOTE:

You must be logged in with Admin privileges to configure the BMC settings.

1

Log in to the Server Administrator home page for the target system.

2

Click the System object.

3

Click the Main System Chassis object.

Advertising