Brocade Adapters Troubleshooting Guide

93

53-1002145-01

Diagnostics

3

Memory test

Use the BCU or the HCM to perform a memory test for the adapter.

NOTE

Performing the memory test disables the adapter.

Performing a memory test through BCU

Use the diag --memtest command to test the adapter’s memory blocks.

diag --memtest <ad_id>

where:

ad_id

ID of the adapter.

Performing a memory test through HCM

Use the Hardware Tests tab on the Diagnostics dialog box as follows to perform a memory test.

1. Launch the HCM.

2. Select Configure > Diagnostics.

3. Click the Hardware Tests tab.

4. Select Memory Test.

5. Specify the test cycle using a positive number.

6. Click Start.

Pinging Fibre Channel end points

Use the BCU and HCM to ping a Fibre Channel end point from an adapter port to determine the
basic connectivity to the remote port and monitor network latency.

NOTE

Ping testing is not supported on Solaris systems.

Issuing a ping command to end points through BCU

Use the fcdiag --fcping BCU command to test the connection to a Fibre Channel end point.

fcdiag -–fcping <port_id> <rpwwn> [-l <lpwwn>]

where:

port_id

ID of the adapter port from which you want to ping the remote port. This could
be the PWWN, port hardware path, or user-specified port name. This could
also be the adapter-index/port-index. For example, to specify adapter 1, port
1, you would use 1/1 as the port identification.

rpwwn

Remote PWWN that you want to ping.

lpwwn

Logical PWWN. 0 indicates the base port.