Brocade Adapters Troubleshooting Guide

53-1002145-01

General adapter problems

2

Action: Try rebooting the system to force a resource rebalance. If the problem persists, increase the
system memory or disable some of the adapter instances.

Installer program does not autorun

On Windows systems, if the installer program does not automatically run from the DVD that you
create with the ISO file containing all supported software installation packages, refer to the
following descriptions of possible causes and recommended actions to help resolve the problem.

NOTE

This ISO file can be downloaded from the Brocade adapters website

at

www.brocade.com/adapters

.

Possible Cause: Autorun is not enabled on your system.

Action: Double-click the "LaunchWinSetup.cmd" file in the root directory of the Installation DVD that
you created with the ISO file. This will launch the installer program.

Action: Refer to

“Installer program does not autorun”

on page 12 for more information to isolate

this problem.

Host system freezes or crashes

If the BIOS and the operating system recognize the adapter, but the host system freezes or crashes
during startup and does not boot, refer to the following descriptions of possible causes and
recommended actions to help resolve the problem.

Possible Causes:

Conflicts with adapter port operating speed or topology of attached devices.

Adapter not compatible with host system.

Faulty fiber optic cabling and connections (stand-up adapters only).

Faulty or unseated SFPs or unsupported SFPs (stand-up adapters only).

Action: Disconnect all devices from the adapter, then reboot the host system.

If the system does not freeze when rebooted and operates correctly, use the following
information to resolve the problem:

a. Check for faulty cable and cable connections.

b. Try rebooting the system without any connectivity to the switch. This will help isolate any

hang caused by switch and device interactions.

c. Reseat SFPs in the adapter (stand-up adapters only). Determine whether the installed

SFPs are faulty by observing LED operation by the adapter ports. If all LEDs are flashing
amber, the SFP is invalid and may not be a required Brocade model. You can also verify
SFP operation by replacing them with SFPs in a known operating condition. If the problem
is resolved after replacement, the original SFP is faulty.

d. Check for conflicts with attached devices. Verify that data speed and connection topology

(for example, point-to-point) for devices attached through the adapter are compatible with
settings on the adapter port. Although auto may be set, configuring settings manually on
the adapter port and devices may allow connection. Also, note that the adapter only
supports point-to-point connection topology. Refer to the Brocade Adapters
Administrator’s Guide
for procedures to configure adapter ports.