Quality of service not functioning, Trunking problems, Only one adapter port participates in trunk – Dell Brocade Adapters User Manual

Page 53

Advertising
background image

Brocade Adapters Troubleshooting Guide

29

53-1002145-01

HBA problems

2

Action: Enter the bcu qos --query command for the adapter port connected to the switch. If the
QoS state is “Unknown” instead of “Online” and total BB-Credits is “zero,” licenses may not be
installed. Verify if licenses are installed by executing the Fabric OS licenseshow command on
the switch. Install licenses as required.

For more information about Fabric OS commands and QoS support, refer to the Fabric OS
Administrator’s Guide
.

2. Possible Cause: QoS is not enabled on both switch and adapter port.

Action: Verify if QoS is enabled for an adapter port using the qos -query <port_id> BCU
command. Verify if it is enabled on the switch using the islShow command.

Action: Verify zones on the switch using the Fabric OS cfgActvShow command.

3. Possible Cause: QoS zones are not created properly on the switch for high, medium, and low

priority targets.

Action: Verify that QoS is configured on the switch using instructions in the Fabric OS
Administrator’s Guide
.

Quality of Service not functioning

NOTE

QoS is not supported on CNAs or Fabric Adapter ports configured in CNA mode.

Quality of Service (QoS) is enabled on an adapter port connected to a supported edge switch, but it
does not appear to be functioning.

Possible Cause: The following licenses must be installed:

-

Adaptive Networking (AN) license.

-

Server Application Optimization (SAO) license.

Action: To determine if these licenses are installed on the connected switch, execute the Fabric OS
licenseshow command on the switch. If licenses are not installed, install them. For more
information about Fabric OS commands and QoS support, refer to the Fabric OS Administrator’s
Guide
.

Trunking problems

This section provides information to resolve problems when N_Port trunking is enabled on
adapters.

Only one adapter port participates in trunk

Only one port on the adapter configured for trunking is participating in the trunk.

1. Possible Cause: The adapter ports are connected to switch ports in different trunk groups.

ports participating in trunking should be connected to the same port group on the switch.

Action: Connect both adapter ports to the same port group on the switch.

2. Possible Cause: Only one adapter port is connected to the switch. The other port is down or not

connected.

Action: Make sure other port is enabled and connected to switch.