Fabric Watch alarm information

From Fabric Watch, you can view two types of reports:

Alarm notifications—Displays the alarms that occurred for a selected class or area.

Alarm configuration—Displays threshold and alarm configurations for a selected class or area.

Viewing an alarm configuration report

Use the Threshold Configuration tab, Configuration Report subtab to display a report of the
configuration for a selected class or area with the following information:

Threshold settings (labeled Threshold Configuration)

Notification settings (labeled Action Configuration)

Element settings (not labeled) — You can scroll through this information, but cannot make
changes.

To view an alarm configuration report, perform the following steps.

1. Open the Fabric Watch window.

2. Select the Threshold Configuration tab.

3. Select a previously configured element from Fabric Watch Explorer (for instructions, refer to

“Enabling or disabling threshold alarms for individual elements”

on page 91).

4. Under Area Selection, select the alarm area report to be viewed.

5. Select the Configuration Report subtab.

This tab displays a report of the configuration for the selected area.

Displaying alarms

Using the Alarm Notification tab, you can view a list of all alarms that occurred for a selected class
or area (

Figure 7

on page 88).

Table 31

describes the columns in this report. You can click the

header of each column to change the way the information is sorted in your view. You can also
right-click the column header and select sort options from a menu.

NOTE

Note that for the FRU class, only the Name, State, and Time columns are displayed. In addition, if
the FRU area is Fan, the Name column refers to either a fan or a fan FRU, depending on the switch
model.

TABLE 31

Alarm notification table fields

Field

Description

Name

The string assigned to the element that had an event

State

The current state of the element

Reason

The event type that was triggered

Last Value

The data value of the element when the event was triggered

Current Value

The current data value of the element

Time

Time when the event occurred