62

Fabric Watch Administrator’s Guide

53-1002752-01

portThConfig command procedures

7

Area: Class 3 (C3) Discards

Unlike the other areas, take a conservative approach for the C3 Discards area. Use the default
settings and configure the alarms for Above. The goal is to determine the high boundary at
which the port would be fenced, so monitor the high boundary and change the settings
accordingly.

Area: Trunk Utilization

Set the high boundary to 75 percent and the alarms to Above and In-Between conditions.
These settings indicate if the 75 percent threshold is exceeded and for how long.

Areas: Primitive Sequence Protocol Error, State Changes, Utilization, Packet Loss

Use the default settings.

E_Port class default settings

Table 17

provides default settings for areas in the E_Port class.

Port fencing can be enabled or disabled for the following areas for the E_Port class:

Link Failure Count

Loss of Synchronization Count

Primitive Sequence Protocol Error

Invalid Transmission Word

Invalid CRC Count

TABLE 17

E_Port class default settings

Area

Description

Default threshold
settings

Default alarm settings

Threshold state

Cyclic redundancy
check (CRC)

Monitors the
number of CRC
errors.

Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100

Below: 0
Above: 0

Informative
Out_of_range

Invalid transmission
words (ITW)

Monitors the
number of invalid
words transmitted.

Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100

Below: 0
Above: 0

Informative
Out_of_range

Class 3 discards
(C3TX_TO)

Class 3 discards
frames due to time
out or destination
unreachable.

Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0

Below: 0
Above: 0

Informative
Out_of_range

Link loss

Monitors the
number of link
failures.

Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50

Below: 0
Above: 0

Informative
Out_of_range

Advertising