Table 33 – Dell POWEREDGE M1000E User Manual

Page 122

Advertising
background image

102

Fabric Watch Administrator’s Guide

53-1002752-01

Port Detail report

10

219 VE HEALTHY 003:37 - - - - - - - - - - - - -

220 VE HEALTHY 002:48 - - - - - - - - - - - - -

221 VE HEALTHY 061:19 - - - - - - - - - - - - -

222 VE HEALTHY 061:19 - - - - - - - - - - - - -

223 VE HEALTHY 061:19 - - - - - - - - - - - - -

NOTE

Output of the Port Detail report depends on the ports that belong to the current Admin Domain
context. If a port does not belong to the current Admin Domain, nothing other than the port number
is displayed for that port.
Example:

“000 ----------------Not a member of current Admin Domain-------------------”

Table 33

lists and describes each item in the Port Detail report.

TABLE 33

Port Detail report columns

Report item

Description

LFA

Link Loss: the number of link loss occurrences out of range for a specified time period.

LSY

Sync Loss: the number of sync loss occurrences out of range for a specified time period.

LSI

Signal Loss: the number of signal loss occurrences out of range for a specified time period.

PER

Protocol Error: the number of protocol errors out of range for a specified time period.

INW

Invalid word. The number of invalid words out of range for a specified time period.

CRC

Invalid CRC: the number of CRC errors out of range for a specified time period.

PSC

Port hardware state changed too often because of fabric reconfiguration.

BLP

Buffer limited port: the switch status changes when a port is in a buffer limited mode based
on the switch status policy.

STM

SFP temperature is out of specifications.

SRX

SFP receive power is out of specifications.

STX

SFP transmit power is out of specifications.

SCU

SFP current is out of specifications.

SVO

SFP voltage is out of specifications.