Sfp monitoring default settings, Table 8 – Dell POWEREDGE M1000E User Manual

Page 64

Advertising
background image

44

Fabric Watch Administrator’s Guide

53-1002752-01

SFP monitoring guidelines and default settings

6

SFP monitoring default settings

The SFP default settings are shown in

Table 8

. The default alarm configuration (log all alarms only

to the error log) is sufficient. It is recommended that you do not allow alerts to go out as SNMP
traps. If other Port class issues are reported, review the error log for any supporting data for SFP
issues.

TABLE 8

SFP class default settings

Area

Description

Default threshold settings Default alarm

settings

Threshold state

Current

Monitors SFP current

Unit: mA
Time Base: none
Low: 0
High: 50
Buffer: 1

Below: 1
Above: 1

Out_of_range
Out_of_range

Receive power
(RXP)

Monitors receive
power in µWatts

Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25

Below: 1
Above: 1

Out_of_range
Out_of_range

Voltage

Monitors SFP
electrical force in
volts

Unit: mV
Time Base: none
Low: 2970
High: 3630
Buffer: 10

Below: 1
Above: 1

Out_of_range
Out_of_range

Temperature

Monitors SFP
temperature

Unit: Degrees C
Time Base: none
Low: -10
High: 85
Buffer: 3

Below: 1
Above: 1

Out_of_range
Out_of_range

Transmit power
(TXP)

Monitors transmit
power in µWatts

Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25

Below: 1
Above: 1

Out_of_range
Out_of_range

Power on hours

Monitors the number
of hours the 16 Gbps
SFP is powered.

Unit: Changes
Time Base: none
Low: 0
High: 0
Buffer: 0

Below: 0
Above: 0

Informative
Informative

Advertising