Table 18 – Dell POWEREDGE M1000E User Manual

Page 86

Advertising
background image

66

Fabric Watch Administrator’s Guide

53-1002752-01

portThConfig command procedures

7

TABLE 18

FOP_Port and FCU_Port class default settings

Area

Description

Default threshold
settings

Default alarm settings

Threshold state

Cyclic redundancy
check (CRC)

Monitors the
number of CRC
errors.

Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100

Below: 0
Above: 0

Informative
Out_of_range

Invalid transmission
words (ITW)

Monitors the
number of invalid
words transmitted.
For Fabric OS
versions 7.1.0 and
later, the ITW
counter includes a
physical coding
sublayer (PCS)
violation. ITW
violations can occur
due to an ITW
violation, a PCS
violation, or both.

Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100

Below: 0
Above: 0

Informative
Out_of_range

Class 3 discards
(C3TX_TO)

Class 3 discards
frames due to time
out or destination
unreachable.

Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0

Below: 0
Above: 0

Informative
Out_of_range

Link loss

Monitors the
number of link
failures.

Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50

Below: 0
Above: 0

Informative
Out_of_range

Signal loss

Monitors the
number of signal
loss errors.

Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0

Below: 0
Above: 0

Informative
Out_of_range

Sync loss

Monitors the
number of loss of
synchronization
errors.

Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50

Below: 0
Above: 0

Informative
Out_of_range

Protocol errors (PE)

Monitors the
number of primitive
sequence errors.

Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0

Below: 0
Above: 0

Informative
Out_of_range

Received packets
(RXP)

Monitors the receive
rate, by percentage.

Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0

Below: 0
Above: 0

Informative
Informative

Advertising