Dell PowerVault 775N (Rackmount NAS Appliance) User Manual

Page 12

Advertising
background image

E0212

VOLT PLANAR
REG

System board is out of acceptable

voltage range; faulty or

improperly installed system board.

See "

Troubleshooting Power Supplies

" in "Troubleshooting

Your System."

E0276

CPU VRM n

Specified microprocessor VRM is

faulty, unsupported, improperly

installed, or missing.

Ensure that supported VRMs of the same type are properly

installed. If the problem persists, replace the VRM (see

Figure 6-9

in "Installing System Options").

E0276

MISMATCH VRM
n

E0280

MISSING VRM
n

E0319

PCI OVER
CURRENT

Faulty or improperly installed

expansion card.

See "

Troubleshooting Expansion Cards

" in "Troubleshooting

Your System."

E0412

RPM FAN n

Specified cooling fan is faulty,

improperly installed, or missing.

See "

Troubleshooting a Cooling Fan

" in "Troubleshooting

Your System."

E0780

MISSING CPU
1

Microprocessor is not installed in

socket 1.

Install a microprocessor in socket 1 (see "

Adding or

Replacing a Microprocessor

" in "Installing System Options").

To identify microprocessor socket 1, see

Figure A-3

.

E07F0

CPU IERR

Faulty or improperly installed

microprocessor.

See "

Troubleshooting a Microprocessor

" in "Troubleshooting

Your System."

E07F1

TEMP CPU n
HOT

Specified microprocessor is out of

acceptable temperature range and

has halted operation.

See "

Troubleshooting System Cooling

" in "Troubleshooting

Your System." If the problem persists, ensure that the

microprocessor heat sinks are properly installed (see

"

Adding or Replacing a Microprocessor

" in "Installing System

Options").

E07F4

POST CACHE

Faulty or improperly installed

microprocessor.

See "

Troubleshooting a Microprocessor

" in "Troubleshooting

Your System."

E07F4

POST CPU REG

E07F4

POST CPU SMI

SMI handler failed to initialize;

faulty system board.

See "

Getting Help

."

E07FA

TEMP CPU n
THERM

Specified microprocessor is out of

acceptable temperature range and

is operating at a reduced speed,

or frequency.

See "

Troubleshooting System Cooling

" in "Troubleshooting

Your System." If the problem persists, ensure that the

microprocessor heat sinks are properly installed (see

"

Adding or Replacing a Microprocessor

" in "Installing System

Options").

E0876

POWER PS n

No power available from the

specified power supply; specified

power supply is improperly

installed or faulty.

See "

Troubleshooting Power Supplies

" in "Troubleshooting

Your System."

E0880

INSUFFICIENT
PS

Insufficient power is being

supplied to the system; power

supplies are improperly installed,

faulty, or missing.

See "

Troubleshooting Power Supplies

" in "Troubleshooting

Your System."

E0CB2

MEM SPARE
ROW

Correctable errors threshold was

met in a memory bank: errors

were remapped to the spare row.

See "

Troubleshooting System Memory

" in "Troubleshooting

Your System."

E0CF1

MBE DIMM
Bank n

Memory modules installed in the

specified bank are not the same

type and size; faulty memory

module(s).

Ensure that all banks contain memory modules of the same

type and size and that they are properly installed. If the

problem persists, see "

Troubleshooting System Memory

" in

"Troubleshooting Your System."

E0CF1

POST MEM 64K

Parity failure in the first 64 KB of

main memory.

See "

Troubleshooting System Memory

" in "Troubleshooting

Your System."

E0CF1

POST NO
MEMORY

Main-memory refresh verification

failure.

Ensure that all banks contain memory modules of the same

type and size and that they are properly installed. If the

problem persists, see "

Troubleshooting System Memory

" in

"Troubleshooting Your System."

E0CF5

LOG DISABLE
SBE

Multiple single-bit errors on a

single memory module.

See "

Troubleshooting System Memory

" in "Troubleshooting

Your System."

E0D76

DRIVE FAIL

Faulty or improperly installed hard

drive or RAID controller.

See "

Troubleshooting Hard Drives

" and "

Troubleshooting a

RAID Controller Card

" in "Troubleshooting Your System."