Invalid configuration information -
please run SETUP program

Incorrect configuration

settings in System Setup

program; NVRAM_CLR

jumper is installed; faulty

system battery.

Check the System Setup configuration settings

(see "Using the System Setup Program" in the

User's Guide). Remove the NVRAM_CLR jumper

(see

Figure A-2

for jumper location). If the

problem persists, see "

Troubleshooting the

System Battery

" in "Troubleshooting Your

System."

Invalid NVRAM configuration, resource
re-allocated

System configuration data

has been ignored.

Check the System Setup configuration settings.

See "Using the System Setup Program" in the

User's Guide.

Invalid SCSI configuration

SCSI cable detected on connector SCSIB
of the SCSI backplane, daughter card
not present

A SCSI cable is connected

to the channel B connector

on the SCSI backplane

board; SCSI backplane

daughter card is not

installed.

If a cable is connected to the SCSIB backplane

board connector, the SCSI backplane daughter

card must be installed. Install the backplane

daughter card (see "

Installing a SCSI

Backplane Daughter Card

" in "Installing

Drives").

Keyboard controller failure

Faulty keyboard controller;

faulty system board.

See "

Getting Help

."

Keyboard clock line failure

Loose or improperly

connected keyboard cable;

faulty keyboard; faulty

keyboard controller.

See "

Troubleshooting the Keyboard

" in

"Troubleshooting Your System."

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Memory address line failure at address,
read value expecting value

Faulty or improperly

installed memory modules.

See "

Troubleshooting System Memory

" in

"Troubleshooting Your System."

Memory double word logic failure at
address, read value expecting value

Memory high address line failure at
start address to end address

Memory high data line failure at start
address
to end address

Memory odd/even logic failure at start
address
to end address

Memory write/read failure at address,
read value expecting value

Memory parity failure at start address
to end address

Memory parity error at address

Faulty or improperly

installed memory modules.

See "

Troubleshooting System Memory

" in

"Troubleshooting Your System."

No boot device available

Faulty or missing

CD/diskette drive

subsystem, hard drive, or

hard-drive subsystem.

Use a bootable diskette, CD, or hard drive. If

the problem persists, see "

Troubleshooting the

Diskette Drive

," "

Troubleshooting a CD Drive

,"

and "

Troubleshooting Hard Drives

" in

"Troubleshooting Your System."

No boot sector on hard- disk

No operating system on

hard drive.

Check the hard-drive configuration settings in

the System Setup program (see "Using the

System Setup Program" in the User's Guide).

No PXE-capable device available

<F12> pressed during

POST and no PXE devices

are detected.

Check the configuration settings in the System

Setup program for the NICs (see "Using the

System Setup Program" in the User's Guide). If

the problem persists, see "

Troubleshooting the

NICs

" in "Troubleshooting Your System."

No timer tick interrupt

Faulty system board.

See "

Getting Help

."

Not a boot diskette

No operating system on

diskette.

Use a bootable diskette.

PCI BIOS failed to install

Loose cables to expansion

card(s); faulty or

improperly installed

expansion card.

Ensure that all appropriate cables are securely

connected to the expansion cards. If the

problem persists, see "

Troubleshooting

Expansion Cards

" in "Troubleshooting Your

System."

Plug & Play Configuration Error

Error encountered in

Install the NVRAM_CLR jumper and reboot the