Carrier 48TM016-028 User Manual

Page 50

Advertising
background image

50

AHA

— Adjustable Heat Anticipator

C

— Contactor, Compressor

CAP

— Capacitor

CB

— Circuit Breaker

CC

— Cooling Compensator

CH

— Crankcase Heater

CLO

— Compressor Lockout

COMP — Compressor Motor
CR

— Control Relay

DM

— Damper Motor

DU

— Dummy Terminal

EQUIP — Equipment
FPT

— Freeze Protection Thermostat

FU

— Fuse

GND

— Ground

HPS

— High-Pressure Switch

HS

— Hall Effect Sensor

HV

— High Voltage

I

— Ignitor

IAQ

— Indoor Air Quality Sensor

IDM

— Induced-Draft Motor

IFC

— Indoor-Fan Contactor

IFCB

— Indoor-Fan Circuit Breaker

IFM

— Indoor-Fan Motor

IGC

— Integrated Gas Unit Controller

L

— Light

LED

— Light-Emitting Diode

LOR

— Lockout Relay

LPS

— Low-Pressure Switch

LS

— Limit Switch

MGV

— Main Gas Valve

NEC

— National Electrical Code

OAT

— Outdoor Air Temperature Sensor

OCCUP — Occupancy Sensor
OFC

— Outdoor-Fan Contactor

OFM

— Outdoor-Fan Motor

PL

— Plug Assembly

PRI

— Primary

QT

— Quadruple Terminal

RAT

— Return Air Temperature Sensor

RS

— Rollout Switch

SN

— Sensor

SR

— Solenoid Relay

SW

— Switch

TB

— Terminal Block

TC

— Thermostat Cooling

TH

— Thermostat Heating

TRAN

— Transformer

Terminal (Marked)

Terminal (Unmarked)

Terminal Block

Splice

Factory Wiring

Field Control Wiring

Option/Accessory Wiring

To indicate common potential
only; not to represent wiring.

Economizer Motor

Remote POT Field
Accessory

OAT Sensor

Disch Air Sensor

RAT Accessory Sensor

Low Ambient Lockout Switch

LEGEND AND NOTES FOR FIG. 57 AND 58

LEGEND

NOTES:

1. Compressor and/or fan motor(s) thermally protected. Three-phase motors protected against primary single phasing conditions.
2. If any of the original wire furnished must be replaced, it must be replaced with Type 90° C or its equivalent.
3. Jumpers are omitted when unit is equipped with economizer.
4. IFCB must trip amps is equal to or less than 140% FLA.
5. On TRAN1 use BLK lead for 460-v power supply and ORN lead for 575-v power supply.
6. The CLO locks out the compressor to prevent short cycling on compressor overload and safety devices; before replacing CLO check these devices.
7. Number(s) indicates the line location of used contacts. A bracket over (2) numbers signifies a single pole, double throw contact. An underlined num-

ber signifies a normally closed contact. Plain (no line) number signifies a normally open contact.

8. 620 Ohm, 1 watt, 5% resistor should be removed only when using differential enthalpy or dry bulb.
9. If a separate field supplied 24 v transformer is used for the IAQ sensor power supply, it cannot have the secondary of the transformer grounded.

10. OAT sensor is shipped inside unit and must be relocated in the field for proper operation.
11. For field installed remote minimum position POT. remove black wire jumper between P and P1 and set control minimum position POT to the mini-

mum position.