Anchoring & sealing, B) temporary glazing usin, A) glass size & glass setting – EFCO 960 Series User Manual
Page 47: Fig. # 40, Fig. # 39, Screw spline / shear block installation

to the exterior,
do not seal
this front
seam.
moisture migration
To allow for
FIG. # 40
Apply sealant to the upturned
leg before setting the unit in place.
FIG. # 39
6" from the ends
OF SEALANT.
KEEP THIS GLAZING
FROM ANY TYPE
LEG FACE FREE
and 24" on center.
Shim and anchor
HEAD AND JAMBS AT
AND THE EXTERIOR.
SEAL THE PERIMETER
BOTH THE INTERIOR
the perimeter
PAGE 45
JDA 6/2002
LEG FACE FREE
FROM ANY TYPE
KEEP THIS GLAZING
OF SEALANT.
silicone type sealant (D.C.795).
Seal horizontal cavities that
are accessible with a
SEAL ALL JAMB CAVITIES
WITH A SILICONE
TYPE SEALANT.
SEALANT
SECTION VIII A -
SCREW SPLINE / SHEAR BLOCK
INSTALLATION
FRAME ANCHORING
Before the fastener is inserted, force
sealant into the hole for the sill
perimeter fastener to ensure that the
hole through the sill flashing is sealed.
Cover the heads of all fasteners
with sealant as shown.
960 WALL