1.4 a. Insert RS-35 Reinforcement Steel into HW-500 Jamb or Mullion

(Steel Height = Mullion Height Minus 6")

b.Prior to HW-185-01 Shear Block attachment insert HW-202-01 Anchor Sleeves at

HW-710 Vertical Mullion ends and match drill .191 dia. hole.

c. Attach HW-185-01 Shear Block to HW-710 Vertical Mullion with FS-9 fastener

d. Attach RS-35 & RS-36 (as applicable) Reinforcement Steel to HW-710 Jamb or Mullion with (2) FS-322

fasteners to be located within the Intermediate Horizontal shear block as show in FIGURE 1.4a

e. Install FG-5185 interior spacer gasket cut to 2" from ends and 2" gaps at

horizontal to allow for HW-355 Zone Plugs.

f. Install and seal HW-345 End Caps to top and bottom of HW-710 Vertical Mullion

screw boss with (2) FS-320 #10 x 1/2" drive screw.

HW-202-01 Anchor Sleeve

HW-710 Intermediate Vertical Mullion

HW-185-01 Shear Block

Drill #25 - .1495" pilot hole

install (2) FS-322 Fasteners

HW-348 for Jambs

and HW-345 for Mullions

Seal and tool sealant

on end caps

St

ee

l H

ei

gh

t =

M

ul

lio

n

H

ei

gh

t M

in

us

6

"

RS-35 Reinforcement Steel

(4) FS-9 Fasteners

FIGURE 1.4

FIGURE 1.4a

(2) FS-320 Drive Screw

VERTICAL MULLIONS WITH STEEL REINFORCEMENT

RELIANCE STORMMAX HIGH PERFORMANCE INSTALLATION MANUAL