Jamb-fabrication – Oldcastle BuildingEnvelope Reliance StormMax High Performance User Manual

Page 8

Advertising
background image

February 2014

06-Jamb-Fabrication

1-866-Oldcastle (653-2278) www.oldcastlebe.com

HW-202-01 Anchor Sleeve

HW-710 Jamb Mullion

HW-185-01

Shear Block

(4) FS-9

Fasteners

(2) FS-320 Drive Screw

HW-348 Jamb End Cap

Apply sealant bed to entire

length of Jamb Mullion

HW-123 Jamb Filler

FS-322

Fastener

locate 12" O.C.

1.2 a. Prior to HW-185-01 shear block attachment insert HW-202-01 Anchor Sleeves at Jamb ends and match

drill .191 dia. hole.

b. Attach HW-185-01 shear block to HW-710 Jamb with FS-9 fastener.

c. Attach HW-123 Jamb Filler to HW-710 Jamb using FS-322 Fastener locate 12" O.C. (Drill #11 - .191"

clear hole in HW-123 Jamb Filler and #25 - .1495" pilot hole in Jamb) HW-123 Filler should be bed

in sealant. Tool sealant on gap space between HW-123 Filler and Jamb Mullion.

d. Install interior FG-5185 Spacer Gasket cut to 2" from ends and 2" gaps at horizontal to allow for

zone plugs. (Not applicable for Dry Glazed applications.)

e. Install, seal and tool HW-348 End Caps to top and bottom of Jamb screw boss with

(2) FS-320 #10 x 1/2" drive screws.

Apply sealant bed to entire front

edge of mullion end prior to

installation of HW-348 Jamb Cap

2"

Gap dimension for

HW-355 Zone Plug

FIGURE 1.2

JAMB FABRICATION

Apply sealant bed to

entire edge of mullion

end prior to installation

of HW-348 Jamb Cap

RELIANCE STORMMAX HIGH PERFORMANCE INSTALLATION MANUAL