Glass-sizing – Oldcastle BuildingEnvelope Reliance StormMax High Performance User Manual

Page 23

Advertising
background image

February 2014

21-Glass-Sizing

1-866-Oldcastle (653-2278) www.oldcastlebe.com

GLASS SIZING AND INSTALLATION

3.2 a. Set glass in opening. Ensure that glass bite is equal on all sides. CAUTION: Be certain that glass is

placed firmly against interior spacer gasket to ensure a proper seal and to avoid binding of the glass on

the setting block.

b. Temporarily hold glass in the opening with WW-333 temporary glazing retainers & FS-325 screw.

Torque the FS-325 screw to 90 in-lbs.

-WW-333 temporary glazing retainers must be applied at each glass edge 3" from the corner (minimum

of 8 per lite). Glass edges greater than 4' in length but less than 8' require an additional retainer at the

glass mid-span.

-Retainers are intended for short term use only. Additional retainers may be required to withstand full

design wind load pressures.

-Full length pressure plates must be installed if severe weather or high wind loads are anticipated.

See Figure 3.2a & 3.2b

HW-355 zone plug

see Figure 4.1 for

sealant notes

CW-2102 setting block

(2) per D.L.O, locate at

1/4 points

WW-333-01 temporary glazing retainer.

Locate at 3" from edge of glass. Additional

clips may be required based on field

conditions and glass size.

FS-325

(1) per retainer

3" typ.

3" typ.

FIGURE 3.2a

Glazing Instructions

FIGURE 3.2b

Typical Location of Temporary

Glazing Retainers

GLASS SIZE CALCULATION

CAPTURED = D.L.O. PLUS 2.00" WIDTH & HEIGHT

RELIANCE STORMMAX HIGH PERFORMANCE INSTALLATION MANUAL