1.6 a. Cut HW-163 Pressure Plate to D.L.O. minus 1/4" for horizontal members.

b. Drill (2) 5/16" weep holes at 1/4 points into corner of raised section at a 45 degree angle of

HW-163 Pressure Plate. See Figure 1.9a

c. Cut HW-163 Pressure Plates vertical members to Frame Height minus 1/4".

d. Cut GP-165 Gasket to D.L.O. plus 3/16" for relaxation on horizontal members. Vertical members

are cut to frame height plus 1/4". Crowd gasket into riglet. See FIGURE 1.6b

PRESSURE PLATE FABRICATION

HW-163 Pressure Plate

Locate weep holes at quarter points

Drill (2) 5/16" weep holes

at a 45 degree angle.

Locate at 1/4 points

of each end of member.

D.L.O

MINU

S 1/4

"

FIGURE 1.6a

Horizontal Pressure

Plate Fabrication

HW-163 Pressure Plate

RELIANCE STORMMAX HIGH PERFORMANCE INSTALLATION MANUAL