18-Zone-Plug-Installation

1-866-Oldcastle (653-2278) www.oldcastlebe.com

HW-355 zone plug

Force sealant

into gasket race

Seal along tongue of

horizontal & across face and

tongue of mullion before

installing HW-355 zone plugs.

STEP 1

STEP 2

Tool sealant along top

of zone plug to form

a water tight seal.

ZONE PLUG AT HEAD

ZONE PLUG AT JAMB

ZONE PLUG AT SILL

Bottom side of

zone plug shown.

Seal top

side similar.

Seal jamb & sill

zone plugs same

as shown at left

Seal between head,

vertical mullion and

mullion cap

Seal between

sill, vertical &

mullion cap

ZONE PLUG INSTALLATION

FIGURE 2.4

2.4 Install and seal as shown in Steps 1 & 2. Use Dow Coring 795 or Tremco Proglaze SSG.

RELIANCE STORMMAX HIGH PERFORMANCE INSTALLATION MANUAL